Clinical pharmacology and pharmacokinetics: questions and answers Part 11

Jan. 05, 2026

7. Biosimilars

 

7.1 What are the key pharmacokinetic considerations in the assessment of biosimilarity? (updated May 2020)

 

Pharmacokinetics (PK) is an integral part of the biosimilarity assessment. A biosimilar product contains a version of the active substance of an already authorised original product (see 'Guideline on similar biological medicinal products containing biotechnology-derived proteins as active substance: non-clinical and clinical issues - Revision 1' EMEA/CHMP/BMWP/42832/2005 Rev1). This is in contrast to small molecule generics where the active substances are chemically identical and, as such, the disposition of the active substance is the same once the compound is absorbed. For a biologically-derived medical product the comparability assessment is more complex, as not only the absorption but also the disposition (distribution and elimination) can differ for a biosimilar compared to the reference product. Therefore, in the assessment of a biosimilar, the PK comparison should also reflect the distribution and elimination processes (e.g. plasma clearance, volume of distribution, half-life) in addition to the absorption.

Biotechnology-derived proteins can be very different in complexity. For example, when evaluating a well-characterisable polypeptide biosimilar without any post-translational modifications having the same structure as the reference product, the probability of differences in disposition of the active substance is considered to be low. On the other hand, differences in glycan structures of complex biologicals or in pegylation may be more likely to affect distribution or elimination characteristics. 

In summary, the comparability PK study for a biosimilar product is a test of formulations and active substance, in contrast to small molecule generics where the comparison of formulations is sufficient. The role of the comparative PK study in the assessment of biosimilarity is to exclude any relevant PK differences that could indicate presence of structural and/or functional differences that could impact the efficacy, safety or immunogenicity of the product. Following are issues that need to be considered in assessment of biosimilarity.

 

Pharmacokinetics

Linear clearance. The simplest case is single IV administration of a compound with concentration independent clearance. In this case clearance (CL) is directly reflected by the primary PK parameter AUC(0-inf) when the same dose of the biosimilar and reference product is given. The extrapolation to AUC(0-inf) from AUC(0-t) for substances having linear elimination is straightforward.

Linear clearance + Nonlinear clearance. For therapeutic proteins the total clearance often consists of a linear (nonspecific) clearance and a nonlinear (target mediated) clearance. Clearance may then be dependent on concentration of the compound itself as well as on the concentration of target and thus target dynamics. Target-mediated clearance may not be evident in the therapeutic concentration range due to saturation of the target, but can be observed at low plasma concentrations when the target is not saturated. AUC(0-inf) includes both nonspecific and target-mediated elimination, but non-compartmental analysis (NCA) cannot differentiate between the two elimination pathways. If pharmacokinetics of the biological medical product is characterised by a non-specific and target mediated clearance, partial AUCs reflecting the different elimination pathways or PK modelling may support the assessment of PK similarity between the biosimilar and innovator product. Knowledge regarding any nonlinearity should, in general, be known from the reference product. However, it may be useful to plot individual PK curves for each treatment group to reveal any patterns or trends that could be masked in the mean plasma concentration time curves.

Some complexity is added for subcutaneously (SC) or intramuscularly (IM) administrated products since AUC(0-inf) then reflects CL/F. For SC and IM administrated products Cmax, in addition to AUC(0-inf), is a primary PK parameter for statistical comparison between the biosimilar and reference product.

 

Anti-drug antibodies

Large variations in PK and nonlinear elimination kinetics can also be caused by an immune response and formation of anti-drug antibodies (ADA) that could increase clearance. If there is a high incidence of ADA formation, it may be useful to visualise the individual PK profiles in subjects with and without ADA. A subgroup analysis of ADA negative and ADA positive subjects comparing PK parameters between treatment groups could be performed if feasible. This analysis should, if possible, be included in the statistical analysis plan.

 

Batch selection and protein content correction

Representative batches of the biosimilar and innovator product should be used in the comparative PK study and it should be documented how the used batches have been selected. When pre-filled syringes, injection pens, etc. are being used, protein content of the batch, as well as delivered volume, should be considered in selection of the batches. The protein content of the selected biosimilar and reference product batches should be determined beforehand and analysed using the same analytical method. Pre-specified and well-justified protein content adjustment can be acceptable, provided that the difference in delivered dose is not reflecting a consistent difference between the biosimilar and reference product (see 'Guideline on similar biological medicinal products containing biotechnology-derived proteins as active substance: non-clinical and clinical issues - Revision 1' EMEA/CHMP/BMWP/42832/2005 Rev1). Furthermore, proportional adjustment for protein content in case of nonlinear pharmacokinetics should be thoroughly discussed. Alternative methods to ensure delivery of the same protein dose could be considered. For example, the same content of the biosimilar and reference product in prefilled syringes could be transferred into identical syringes, thus avoiding any dose correction due to the device or protein content. Such a solution requires further discussion on potential effects of the devices on the delivered doses, where needed, supported with additional data, e.g. looking for systematic differences in delivered volume, effects of needle size etc., to support that there is no difference in local delivery of the product.

 

Study Design

Parallel design is often utilised due to long half-life or the risk of an immunogenic response. It is important to scrutinise the pre-specified exclusion criteria for individual PK data and for which PK parameters the criteria are valid. After exclusion of subjects for pre-specified reasons, it should be examined whether the groups are balanced and if not, whether this could affect the results (i.e. discuss the robustness of the results in case the fraction of excluded subjects was large e.g. by PK modelling). If a cross-over design is being used, the length of wash out need to be well supported taking active substance and any PD marker that is measured as study endpoint into account. For comparability reasons, a cross-over study design is preferred as the subject is its own control, however, in case of relevant ADA incidence, appropriateness of cross-over design is generally questioned. Even if ADAs are washed out, an increased sensibility for ADA development is carried over to the second period. Besides ADAs, potential effects on target density should be considered as well. When target-mediated clearance is relevant, any change in target density as a result of treatment could affect clearance and thus contribute to a carry-over effect.

Study population. The selected study population should be justified and the sensitivity for detecting PK differences should be considered when assessing the PK study. The variability is in general less in healthy volunteers and therefore, they are generally acceptable as study population in the PK study. However, it should be considered that the target density may be different in healthy volunteers vs. patients and patients in different therapeutic areas or severity of disease. In case both target mediated and non-target mediated elimination need to be considered, comparable PK should preferably be supported for the predominant (or both) mechanism(s). This could in some cases be handled by dose selection (see below). If not, other supportive data could be collected. This could include partial AUCs under the target mediated elimination phase in the healthy volunteers as well as concentrations measured during the efficacy, safety and/or PD studies. For example, through at different time points during the treatment can be used as a supportive PK parameter. 

Dose level. If possible, the most sensitive dose should be selected to investigate any target mediated clearance. The dose selection is of particular importance when target mediated clearance is expected to be larger in the patient population compared to healthy subjects. In such case a low dose (i.e. assuming target is not saturated) or the lowest recommended therapeutic dose and a high dose, usually the highest recommended therapeutic dose (assuming target is saturated and non-specific CL is dominating), should be considered for PK comparison (see 'Guideline on similar biological medicinal products containing monoclonal antibodies – non-clinical and clinical issues' EMA/CHMP/BMWP/403543/2010).   

Sampling times. It is important to ensure long enough plasma sampling also considering subjects with the longest half-life to avoid large extrapolations when estimating AUC(0-inf). This is particularly important when clearance is nonlinear, which can slightly overestimate AUC(0-inf), as the extrapolation to AUC(0-inf) using non-compartmental analysis assumes linear elimination. An extrapolated AUC of ?20% is considered to be acceptable. In line with the requirements for chemical entities, subjects should not be excluded from the statistical analysis if the extrapolated AUC is >20%. However, if the percentage AUC(0-t) ?80% of AUC(0-inf) in more than 20% of the observations then the validity of the study may need to be discussed.

 

Statistical Comparison

Acceptance criteria. The acceptance criteria for the main PK parameters should be defined and justified prior to conducting the study based on obtaining a precise quantification of relative exposure and including consideration of differences in those parameters that are unlikely to have any clinically relevant impact on pharmacodynamic response. In the absence of a rigorous clinical justification, acceptance criteria of 80–125% might be used, but this might have consequences for interpretation of trial results (see below).

Analysis. Typically, the comparability of the PK parameters is analysed using ANOVA, which is adequate for the analysis of a cross-over trial. However, for a parallel group study it may be desirable to adjust for baseline characteristics that could affect the PK results (e.g. body weight) and which may be imbalanced between the two treatment arms. Therefore, analysis of comparability of the PK parameters by ANCOVA is acceptable in parallel group studies, provided that the choice of covariates has been justified and this is pre-specified in the statistical analysis plan. It should be noted that this model cannot be used to adjust for any covariates measured after randomisation, such as ADA formation.

Statistically significant difference. As stated in the introduction, the active substance in a biosimilar is not exactly the same as the innovator product and the purpose of the clinical comparability studies is not to show the products are identical, but to exclude an important impact arising from any functional or structural differences compared to the reference product. Therefore, a biosimilar product should be considered to be acceptably similar to the reference product in terms of PK if the 90%-CIs for the primary PK parameters are contained within the pre-specified and justified acceptance limits. In the absence of rigorous and acceptable justification for the pre-specified acceptance criteria and, in particular where 80–125% is chosen rather arbitrarily, a point estimate or substantive part of the confidence interval lying towards the extremes of the acceptance criteria will require further discussion.  This includes instances where unity is excluded from the 90% CI. Specifically, results should be explained and justified in the context of evidence for similarity coming from other comparative studies/assays within the development programme. 

If the 90%-CIs for the primary PK parameters are not contained completely within the pre-specified acceptance limits, a root cause analysis should be initiated. Findings from the root cause analysis should be reflected in the planning and conduct of any subsequent PK study, but any changes to the design should not compromise the sensitivity of the study to detect differences if they exist. Even in the presence of identified root causes, it is very important for assessment to understand why the evidence of failed PK comparability can be disregarded with plausibility.

In case uncertainties concerning root causes remain, or if no causes could be identified, assessment of PK similarity should be based on results from both the original and subsequent PK studies. The existence of a study which demonstrates biosimilarity does not mean that those which do not can be ignored. It should be thoroughly discussed and justified that the biosimilarity claim has been demonstrated overall, and that the evidence from the positive study or studies is sufficient to dominate the results from those that were not. Where relevant, a combined analysis of all studies can be provided in addition to the individual study analyses as part of this justification. It is not acceptable to pool together several negative studies to justify PK biosimilarity in the absence of a study that is positive alone.

 

Limitations of the PK study

It is important to be aware that the comparative PK study cannot be used to outweigh substantial differences in quality, non-clinical or efficacy and safety studies. The results of the PK investigations should always be interpreted and weighed in the context of all other data. The extent to which potential differences in disposition between biosimilar and reference product could occur depends on the nature of the molecular differences between both products. It is therefore important to consider also the quality characteristics and data on binding properties when judging the likelihood of potential pharmacokinetic differences.

 

8. Modified release products

 

8.1 PKWP is requested to provide clarification on the requirements for sensitisation and irritation tests for transdermal products in Appendix I of the Guideline on the pharmacokinetic and clinical evaluation of modified release dosage forms. June 2018

 

Appendix I of the Guideline on the pharmacokinetic and clinical evaluation of modified release dosage forms (EMA/CPMP/EWP/280/96 Corr1) defines the situations where skin irritation and sensitisation should be assessed for transdermal products and recommends study designs and scoring systems that can be used accordingly.

These general requirements of Appendix I remain valid, however, this Q A has been developed to clarify aspects of study designs and scoring systems to reflect the evolving scientific knowledge on the topic as follows:

The Appendix suggests one overall study design and it is now emphasised that this design is likely to need adoption to the particular question(s) to be addressed regarding e.g. specific formulation characteristics, differences in composition as compared to the innovator and intended dosing intervals.

Due to scientific and ethical reasons sensitisation testing by means of the human repeat insult patch test as described should be conducted in exceptional cases only as subjects might unnecessarily be sensitised and the sample size may not include sensitive subjects (i.e. individuals that would actually react).

As examinations of skin reactions is highly subjective this should be done by trained and experienced persons blinded to the treatment.

Other numerical scores than the dermal response (Table 1) and other effect (Table 2) scores that are currently presented in the Appendix have been found to be more appropriate (e.g. for Table 1, 'definite oedema' does not happen in isolation to 'erythema' and 'papules'. For Table 2, the use of the term 'glazing' is deemed more likely with cosmetics rather than transdermal patches). The following scores may therefore be considered as possible alternate examples, but it is acknowledged that still others are available in the literature and the choice of score should be appropriately justified:

Table 1: Seven-point dermal response scale*

*German Contact Dermatitis Group (Schnuch A, Aberer W, Agathos M, Becker D, Brasch J, Elsner P, Frosch PJ, Fuchs T, Geier J, Hillen U,Loeffler H, Mahler V, Richter G, Szliska C, fuer die Deutsche Kontaktallergie?Gruppe (2007) LEITLINIEN DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT (DDG) UND DER DEUTSCHEN GESELLSCHAFT FUER ALLERGIE? UND KLINISCHE IMMUNOLOGIE (DGAKI) ZUR DURCHFUEHRUNG DES EPIKUTANTESTS MIT KONTAKTALLERGENEN; issued 14.11.1998, updated 4.5.2007)

In conclusion, applicants are advised to use Appendix I and this QA to address sensitisation and irritation testing of transdermal patches carefully, taking account of product characteristics and based on current knowledge.

 

9. Well-established use

1. What are the bridging requirements for formulations in a well-established use application? July 2025

 

1.1. Introduction

This guidance is aimed at further clarifying the requirements for bridging data in the context of well-established use (WEU) applications, i.e. when an active ingredient of a medicinal product has been in well-established use for at least 10 years within the Union with a recognized efficacy and an acceptable level of safety. This should be read in conjunction with Annex I (Part II.1) of Directive 2001/83/EC and the Notice to Applicants Volume 2A - Chapter 1 ‘Marketing Authorisation’.

Pre-clinical and clinical documentation for WEU marketing authorisation (MA) applications is based on results from the scientific literature. As outlined in Part II of the Directive´s Annex I, bridging data should be provided to justify that the data from the scientific literature, presented to support safety and efficacy of the active substance(s), are relevant for the medicinal product in the application: “The non-clinical and/or clinical overviews must explain the relevance of any data submitted which concern a product different from the product intended for marketing. A judgement must be made whether the product studied can be considered as similar to the product, for which application for a marketing authorization has been made in spite of the existing differences.”

In drafting the present guidance, the experience acquired with previous assessments of WEU MA applications was taken into consideration. The guidance aims to support Applicants in preparing these applications and facilitate predictable and scientifically robust assessment. It is highlighted that the relevance of data provided to establish the bridge in the context of WEU applications is a matter of scientific assessment by the relevant competent authority assessing the application.

It is important to bear in mind that applications according to Article 10a of Directive 2001/83/EC are acceptable only in so far as the published scientific literature is relevant and sufficient to demonstrate the safety and efficacy profile of the medicinal product in the proposed therapeutic indication that is the object of the application. Alternative legal basis should be considered in case the applicant intends to include own clinical or pre-clinical data (with the exception of relative bioavailability data). WEU applications are not an alternative to other legal bases such as Article 10(1) and 10(3) of Directive 2001/83/EC, but the principles regarding the scientific requirements for bridging between the relevant formulations shall remain the same.

Because the safety and efficacy profile of biological medicinal products is determined by the manufacturing process and the starting materials, it is unlikely that only literature data would be sufficient to establish that the pertaining active substances do not significantly differ in terms of safety and/or efficacy. As a consequence, it is difficult to demonstrate that the product applied for is sufficiently similar to the one(s) used in the literature. Alternative appropriate legal basis should be considered for applications for biologicals.

Although there are no restrictions regarding dosage forms being within the scope of a WEU application, bridging of products that have modified release characteristics or which are topical/transdermal formulations may be particularly challenging. The Applicant should either demonstrate that the products studied in literature are identical to the Applicant’s product or provide adequate bridging data in line with applicable guidelines (see Section 1.2.2).

Literature from outside the EU can be used to support the safety and efficacy profile. However, the Applicant should also place special emphasis on the possibility of bridging to other EU products containing the same constituents. It is reminded that the Applicant has to demonstrate that the active substance has been in well-established use in the Union for at least 10 years.

 

1.2. Bridging requirements

1.2.1. What to bridge to (what to compare)?

In the context of a WEU application, although those applications are self-standing contrary to abridged applications such as generics, hybrids or biosimilars that refer to a reference medicinal product, a bridging exercise between the medicinal product applied for and the product(s) used in the scientific literature must be conducted to demonstrate that any cited literature data in support of efficacy and safety is relevant to the specific medicinal product applied for. Therefore, it is essential that the Applicant identifies which product(s) are used in the studies in support of efficacy and safety and whether these are still available on the market.

The Applicant should submit summary tabulated data to facilitate the assessment with at least the following details (to be placed in Module 2.5, heading Overview of biopharmaceutics):

Comprehensive information on the exact product(s) (formulation(s)) that have been used in the efficacy and safety studies referred to in the literature, including detailed information on which aspects (efficacy/safety, proposed indications) of the dossier should be covered by these studies. If information on the formulation(s) that have been used is not available, this should be stated. In such case, a general overview of all available and used formulations over time may be helpful. Details of these study results need not be part of the table but should be provided elsewhere in the dossier. Efficacy and safety studies that are considered particularly relevant (i.e. pivotal) should be highlighted.

A justification for the bridge to support a judgement being made on whether the product(s) studied in the literature can be considered as similar to the product for which an application for a marketing authorization is being made.

Which scientific literature is considered pivotal with respect to the demonstration of efficacy and safety for the application made. In cases when no pivotal literature is available, or can be identified, other literature may be acceptable when adequately justified. Combined information from multiple studies is likely needed to reasonably support efficacy and safety as an overarching assessment.

If the benefit-risk balance is based on multiple literature studies including different products per indication applied for, bridging data for each indication is preferred. If sufficiently justified, bridging only to the indication with the most evidence and/or with clearly identified pivotal studies could also be an option, e.g. when the mode of action is the same for all indications claimed. Alternatively, the Applicant could use a bracketing approach to claim that the applied product is in between the products described in the literature. Ultimately, this will be a case-by-case approach, which requires sound scientific justification.

 

1.2.2. How to form the bridge?

As a general statement, the applicable guidelines should be followed depending on the product; e.g., for systemically acting products: EMA Guideline on the investigation of bioequivalence (CPMP/EWP/QWP/1401/98 Rev 1/Corr), ICH M13A Guideline on bioequivalence for immediate-release solid oral dosage forms (EMA/CHMP/ICH/953493/2022), ICH M9 Guideline on biopharmaceutics classification system based biowaivers (EMA/CHMP/ICH/493213/2018), EMA Guideline on the pharmacokinetic and clinical evaluation of modified release dosage forms (EMA/CPMP/EWP/280/96 Corr1), and relevant EMA product-specific bioequivalence guidelines.

Furthermore, bridging focusses on the formulation and absorption aspects as the distribution and elimination properties tend to be independent from the formulation for IR products. For modified release products providing adequate bridging data within a WEU application will be more difficult unless products can be shown to be identical or comparative bioavailability (PK) data are submitted.

Depending on the information in the literature, several scenarios can be distinguished:

If pivotal literature data are obtained with one single product, the Applicant would normally need to provide adequate bridging data to this product conforming with the requirements for generic applications.

If no comprehensive set of pivotal studies can be identified in the literature, efficacy and safety will mostly be based on an overarching assessment of all potentially relevant literature. For some active substances, there are many different products/formulations included in the pivotal literature. In both cases, an overview can be made of the range of formulations used, based on release characteristics, BCS class, formulation type, excipients, regimen, etc., (“formulation space”). A bracketing approach to claim that the applied product is in between the products described in the literature may be possible. Then there may not be a need for strict bioavailability data compared to a specific product since efficacy and safety has been demonstrated for many different products/formulations. This decision must, however, still take account of individual differences for the product applied for compared to other products as described in the provided literature (see also Section 1.2.2.2. ).

None of the products from the pivotal efficacy and safety studies can be identified. On a case-by-case basis, it may be considered to request the authors from a specific publication for the product information. If no product can be identified, in general this would mean that no bridge can be made, and another application procedure should be considered. An exemption might be made for solutions without excipients that affect the disposition, e.g. for aqueous solutions for intravenous administration.

The product that has been used in the pivotal studies is not available anymore. A direct bridge is not possible, and an indirect bridging may be possible, if scientifically justified. Other products from the market may be selected, but selection criteria must be clear (e.g. on use in Europe) and those products should be shown to be representative for the product(s) studied in literature.

For bridging to the product described in the literature, a tabular overview of the formulations and an excipient comparison needs to be presented. Further, the characteristics of the active substance (e.g. hydrate/solvate, polymorphic form, solubility) and type of formulation(s) (e.g. solution, immediate release (IR) solid formulation) and route of administration (e.g. oral, parenteral) should be presented. Also, the therapeutic window of the product should be discussed.

The requirements for bridging data to support “similarity” may vary depending on how critical it is to demonstrate similar bioavailability between the product applied for and the products studied in the literature and will be further discussed in the next sections. Bridging is generally based on one or more of the following:

comparison of qualitative and quantitative composition of the product;

comparison of critical quality attributes;

comparative in vitro dissolution data;

comparison of physico-chemical properties;

comparative in vitro release or permeation tests in case of a locally applied locally acting product;

comparative bioavailability (PK) studies;

clinical justification for the lack of comparative bioavailability studies.

 

1.2.2.1. Similar bioavailability considered critical

For most drug products, demonstration of similar bioavailability is considered critical; exceptions are mentioned in the next section. It should be demonstrated that any differences in formulation between the product(s) studied and the product applied for do not affect efficacy or limit extrapolation of safety data in all cases.

For IR solid oral dosage forms with systemic action with BCS Class I and III substances, bridging data may be in vitro comparative dissolution data generated by the Applicant between products used in the literature and the product applied for, in line with ICH M9 Guideline on biopharmaceutics classification system based biowaivers (EMA/CHMP/ICH/493213/2018). Similarly, for oral solutions and parental solutions, if criteria for biowaiver are fulfilled, this should be considered as a sufficient bridge.

In case in vitro similarity may not replace a PK bridge, like for BCS Class II and BCS Class IV active substances, or BCS Class I or BCS Class III substance with a different pharmaceutical form than that used in the literature, or the criteria for an in vitro waiver are not met, a clinical comparative bioavailability (PK) study should be conducted with reference to the relevant literature product(s) according to the relevant guidelines. This study should show comparable PK, i.e. similar bioavailability. Wider acceptance ranges than 80-125% may be acceptable, when justified a priori using the submitted literature efficacy and safety studies.

For products that are locally applied and locally acting (LALA), similarity based on in vitro data is commonly an effective bridge. There are, however, cases for such products where PK data may be needed for bridging of LALA products. Reference is made to relevant guidelines for locally applied, locally acting products (e.g., EMA Guideline on equivalence studies for the demonstration of therapeutic equivalence for locally applied, locally acting products in the gastrointestinal tract (CPMP/EWP/239/95 Rev. 1, Corr.1*) and associated decision trees, EMA Guideline on the requirements for clinical documentation for orally inhaled products (OIP) (CPMP/EWP/4151/00 Rev. 1) and Guideline on quality and equivalence of locally applied, locally acting cutaneous products (EMA/CHMP/QWP/708282/2018)).

 

1.2.2.2. Similar bioavailability considered less critical

For certain products, for example, for some orally administered products that contain substances that occur endogenously (vitamins, calcium, iron), it is not feasible to determine bioavailability as the uptake of many of these substances is regulated by homeostatic mechanisms. However, the exact bioavailability is often not relevant for their therapeutic use, and this can be taken into account in the bridging requirements. In such cases, the formulation should be shown to be sufficiently similar to the formulations used in the literature (within the formulation space) with a relevant quality attribute measured.

This could also be applicable when the Applicant can show that there are many different formulations with comparable efficacy and safety, so no different efficacy or safety is expected for the product applied for without having to fulfil specific bracketing requirements.

Examples of justifications/criteria that have been taken into account for such an approach to bridging are (often in combination):

Wide therapeutic index;

Many different formulations or dose regimens have been shown to be effective in the indication(s) applied for and so are supported by a large volume of literature;

Dose individually titrated based on efficacy and safety with wide dose ranges e.g. digestive enzymes;

Bioavailability difficult to be exactly determined, e.g. for endogenous substances whose levels are regulated by homeostatic mechanisms;

Substitution therapy aiming (long-term) to build up body depots of e.g. vitamins;

Other sources like food and sunlight leading to variation in daily exposure to drug substance.

 

Source: EMA

Applications of HEK293 Cells in Modern Protein Engineering

Square Media Bottles PET PETG

EMA Quality of medicines questions and answers: Part 1

Cell Culture Vessels

Related Products

Related News

  • wechat

    Ella: +86 13373342369

Chat with Us