The European Medicines Agency (EMA) has updated its Questions and Answers for Biological Medicinal Products, introducing new and revised recommendations covering the quality development, manufacturing, and control of biological medicinal products.

The updates, published on 20 July 2026, address several important topics for biologics, vaccines, biosimilars, and gene therapy developers, including AAV vector testing, master cell bank changes, vaccine potency assays, viral filtration, endotoxin testing, and quality comparability.

 

New Guidance for AAV Gene Therapy Products

EMA has updated its recommendations for AAV gene therapy products, particularly regarding infectious titer testing.

While the TCID₅₀ assay remains a commonly used method, EMA states that alternative potency assays may be acceptable if applicants can demonstrate that they adequately assess both cell transduction and transgene expression, and are sufficiently sensitive to detect changes in infectivity.

In such cases, infectious titer testing may no longer be required as a routine batch release test, although it should still be retained as part of product characterization.

 

Master Cell Bank Changes Require Careful Evaluation

The updated Q&A also clarifies expectations for Master Cell Bank (MCB) changes.

According to EMA:

Establishing a new clone through retransfection, even when using the same mammalian cell line, will generally require submission as a line extension.

Replacing a cell bank without retransfection may, depending on the circumstances, be handled through a post-approval variation.

This clarification highlights the importance of maintaining well-documented cell bank management and change control throughout the product lifecycle.

 

Vaccine Potency Testing Should Reflect the Final Product

For vaccines, EMA reinforces that potency testing should generally be performed on the final container product, rather than only on the final bulk material.

Only in scientifically justified situations may an alternative approach be accepted.

The recommendation emphasizes that product quality should be confirmed in the same presentation intended for clinical use and commercial distribution.

 

Viral Filtration and Endotoxin Testing Receive Additional Attention

EMA also provides more detailed recommendations for manufacturing controls.

For virus filtration, applicants should identify the specific manufacturer and model of both virus filters and prefilters in regulatory submissions. Generic references to "equivalent filters" are not considered sufficient, as changes to filter models may require additional viral clearance studies.

The Q&A further states that information on pre-use integrity testing should be included in CTD Module 3. Even when pre-sterilized single-use filters are employed, manufacturers should clearly describe supplier testing and in-process control strategies.

Regarding endotoxin testing, EMA encourages the gradual transition from traditional Limulus Amebocyte Lysate (LAL) assays to non-animal-derived methods, such as Recombinant Factor C (rFC) and recombinant cascade reagent technologies.

 

Biosimilar Quality Requires More Than Pharmacopoeial Compliance

Another important clarification relates to biosimilar quality assessment.

EMA notes that compliance with the European Pharmacopoeia alone is not sufficient to demonstrate biosimilarity.

Manufacturers should establish quality ranges based on comprehensive analytical comparability studies between the proposed biosimilar and the reference product.

This reinforces the principle that biosimilar development relies on a totality of evidence, with analytical and quality comparability remaining fundamental components of regulatory evaluation.

FDA Clarifies CMC Flexibilities for Cell and Gene Therapy BLA Applications

Implications for Biopharmaceutical Manufacturers

The updated EMA Q&A demonstrates the continued focus on science-based manufacturing and quality management across biologics, vaccines, biosimilars, and gene therapies.

Several updates have direct implications for manufacturing operations, including:

Master Cell Bank and Working Cell Bank management

Cell culture process consistency

Supplier qualification and material traceability

Single-use filtration systems and change control

Batch-to-batch consistency

CTD quality documentation

As regulatory expectations continue to evolve, manufacturers benefit from reliable production materials supported by complete quality documentation, lot traceability, and controlled change management.

FDCELL supplies sterile Cell Culture Flasks, Cell Factories, Erlenmeyer Shake Flasks, Media Bottles, and other cell culture consumables designed to support research, process development, and commercial biopharmaceutical manufacturing with consistent quality and comprehensive documentation.

 

Source

European Medicines Agency (EMA)

Questions and Answers for Biological Medicinal Products

EMA Update Date: 20 July 2026

Related Products

Related News

  • wechat

    Ella: +86 13373342369

Chat with Us