Guideline on immunogenicity assessment of monoclonal antibodies intended for in vivo clinical use

Dec. 17, 2025

Executive summary 

This guideline addresses issues relating to the unwanted immunogenicity of monoclonal antibodies (mAbs) intended for clinical use. These include factors impacting on immunogenicity of mAbs, the clinical consequences of immunogenicity, assay related problems, assessing neutralizing antibodies induced by mAbs and consideration of a risk-based approach for the evaluation of immunogenicity of mAbs.

 

1. Introduction (background)

Immunogenicity can be a significant problem in the treatment of patients with therapeutic biologicals and this is addressed in the ‘Guideline on Immunogenicity Assessment of Biotechnology-Derived Therapeutic Proteins’ by the CHMP (adopted April 2008, referred to henceforth as ‘the general guideline’), which in principle is applicable to monoclonal antibodies (mAbs). While many aspects of immunogenicity of mAbs are not different from those for other therapeutic proteins, there are several aspects that require more specific considerations. MAbs are not expected to induce antibodies that cross-react and neutralize an endogenous counterpart (as can occur with EPO) and are not used as replacement therapies.

 

Often mAbs are used as therapeutic or diagnostic agents where alternative treatments or diagnostics may exist. However, some specific aspects of immunogenicity are exclusively or primarily relevant for mAbs or novel mAb derivatives (e.g. Fab fragments, scFv, nanobodies, minibodies) and these are addressed in this guideline. MAbs comprise a large important class of therapeutic biologicals. The range of clinical indications with potential for treatment with mAbs is very wide. Many mAb products are known to be associated with unwanted immunogenicity and in some cases the immunogenicity causes impaired clinical responses or rare serious adverse reactions which require clinical intervention. The wide range of mAbs in development, and approved for different clinical indications precludes specific guidelines that are pertinent to all situations.

 

2. Scope

The general principles adopted and explained in this document apply to the development and systematic evaluation of an unwanted immune response against a therapeutic or in vivo diagnostic mAb in recipients. The guideline applies to mAbs, their derivatives, and products of which they are components, e.g., conjugates, Fc linked fusion proteins.

 

This guideline considers the major quality and clinical aspects that are important for adequately addressing the problems with detection of and risk related to the development of an unwanted immune response to the particular mAb in the particular clinical indication sought. This guideline is aimed at products at final development stage (e.g. marketing authorization application stage). However, many of the principles are relevant to earlier phases of development.

 

3. Legal basis

Directive 2001/83/EC, as amended in particular in Directive 2001/83/EC Art 10(4) and Part II of the Annex I of Directive 2001/83/EC, as amended. This guideline should be read in conjunction with other relevant guidelines, e.g.:

Guideline on similar biological medicinal products (CHMP/437/04)

Guideline on similar biological medicinal products containing biotechnology-derived proteins as active substance: non-clinical and clinical issues (EMEA/CPMP/42832/2005).

Guideline on production and quality control of monoclonal antibodies and related substances (EMEA/CHMP/BWP/157653/2007).

ICH guideline S 6 (R1) Preclinical safety evaluation of biotechnology-derived pharmaceuticals (EMA/CHMP/ICH/731268/1998). ·

Guideline on Immunogenicity Assessment of Biotechnology-derived Therapeutic Proteins (EMEA/CHMP/BMWP/14327/2006).

European Pharmacopeia monograph on monoclonal antibodies.

Guidelines on comparability of biotechnology-derived medicinal products after a change in the manufacturing process: non-clinical and clinical issues (EMEA/CHMP/BMWP/101695/2006).

Guideline on bioanalytical method validation (EMEA/CHMP/EWP/192217/2009).

Eudralex Volume 9A of the Rules governing Medicinal Products in the European Union (Part I, Chapter 3: Requirements for Risk Management Systems) to be replaced by Good Vigilance Practice (Volume on Risk Management Systems) after July 2012.

 

4. Problems experienced with screening and confirmatory assays used in assessing immunogenicity of mAbs

4.1. Assays for antibody detection

 

In principle, any immunoassay format can be used to measure antibodies against mAbs. However, assays used to detect antibodies against mAbs are often more problematic, difficult and can be technically challenging. Many standard assay formats involve the use of anti-immunoglobulin reagents such as antibodies against immunoglobulins, protein A or protein G, but these are inappropriate for use in detecting antibodies against mAbs as they very often bind to the product itself. Thus, for example simple ELISAs and radio-immunoprecipitation assays are not usually suitable for use with mAbs unless they are adapted to overcome this problem. Therefore, different assay approaches have to be developed for mAbs.

 

A common approach is to use the ‘bridging’ format e.g. for ELISAs or electrochemiluminescence (ECL) assays which does not require anti-immunoglobulin reagents and so can be directly applied to studies with mAbs. In some cases, this procedure may be less sensitive than other immunoassay methods and may require significant development effort to produce a suitable assay. It also will not efficiently detect the IgG4 antibodies which can be produced in some cases. Another approach is to use a Surface Plasmon Resonance (SPR) procedure. This does not require antiimmunoglobulin reagents for detecting antibodies against mAbs.

 

It is a real-time procedure and is therefore fast and also detects rapidly dissociating antibodies which can be missed by other methods. However, as SPR simply detects protein binding to the coated chip it needs to be confirmed that the signal is caused by antibodies. It may be less sensitive than other methods for detecting high affinity antibodies and, in the absence of automated sampling systems may have a low throughput. Samples (normally serum or plasma) may contain substances that interfere with the assays i.e. matrix effects which produce false positive or negative results and/or incorrect assessment of antibody content.

 

Well known examples of such interfering substances are complement components, mannose binding protein, Fc receptors, soluble target molecules, complement receptor 1 and rheumatoid factors, but other substances including the product itself can also cause problems. Assays often need to be ‘tailored’ to reduce artefacts and achieve acceptable background signal levels, sensitivity and specificity. Applicants need to justify the suitability of the chosen approach, taking into full consideration the limitations of the respective methods.

 

Source: EMA

Original link:https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-immunogenicity-assessment-monoclonal-antibodies-intended-vivo-clinical-use_en.pdf

 

 