INTRODUCTION
This guidance provides recommendations on how to meet provisions of part 320 (21 CFR part 320) for all drug products. This guidance replaces prior FDA guidance for industry of the same name issued in February 2001 (2001 guidance). Part 320 sets forth requirements for (1) submitting bioavailability (BA) and bioequivalence (BE) data in investigational new drug applications (INDs), new drug applications (NDAs), and abbreviated new drug applications (ANDAs), as well as amendments and supplements to these applications; (2) the definitions of BA and BE; and (3) the types of in vitro and in vivo studies that are appropriate to measure BA and establish BE.2
In general, FDA’s guidance documents do not establish legally enforceable responsibilities. Instead, guidances describe the Agency’s current thinking on a topic and should be viewed only as recommendations, unless specific regulatory or statutory requirements are cited. The use of the word should in Agency guidances means that something is suggested or recommended, but not required.
Overview
This guidance provides recommendations to applicants who intend to use equivalence criteria in analyzing in vivo or in vitro BE studies for INDs, NDAs, and ANDAs as well as amendments and supplements to these applications.3 This guidance discusses statistical approaches for BE comparisons and focuses on how to use these approaches both generally and in specific situations. This guidance provides recommendations on the topics covered in the 2001 guidance, including average BE and population BE, study design, logarithmic transformation, studies in multiple groups, carryover effects, and outliers, as well as recommendations on additional topics,
including missing data and intercurrent events, adaptive design, and specific situations, such as narrow therapeutic index (NTI) drugs and highly variable drugs.
The evaluation of relative BA involves the BE comparison between a test product (test or T) and a reference material (reference or R), where T and R can vary depending on the comparison to be performed (e.g., to-be-marketed formulation versus clinical trial formulation, generic drug versus reference listed drug (RLD), originally approved formulation versus postapproval change(s) formulation). Although BA and BE are closely related, BE comparisons normally rely on (1) a criterion, (2) a confidence interval for the criterion, and (3) a predetermined BE limit. BE comparisons could also be used in certain pharmaceutical product line extensions, such as additional strengths, new dosage forms (e.g., changes from immediate release to extended release), and new routes of administration.4 In these contexts, the approaches described in this guidance can be used to determine BE. The general approaches discussed in this guidance may also be useful when assessing pharmaceutical equivalents (i.e., drug products in identical dosage forms and route(s) of administration that contain identical amounts of the identical active drug ingredient)5 or performing equivalence comparisons in clinical pharmacology studies and other areas.
This guidance is intended to encourage the use of science-based approaches to making statistical BE assessments. Given the evolving nature of statistical approaches and technologies, FDA encourages generic and new drug applicants to propose and discuss novel methodologies, such as model-based BE or novel adaptive designs, with the Agency through appropriate regulatory meetings or controlled correspondences, as described below.
B.Statistical Guidance Background
In the July 1992 guidance for industry Statistical Procedures for Bioequivalence Studies Using a Standard Two-Treatment Crossover Design (the 1992 guidance), the Center for Drug Evaluation and Research (CDER) recommended that a standard in vivo BE study design be based on the administration of either single or multiple doses of T and R to healthy subjects on separate occasions, with random assignment to the two possible sequences of drug product administration. The 1992 guidance further recommended that statistical analysis for pharmacokinetic (PK) measures, such as area under the curve (AUC) and peak concentration (Cmax), be based on the two one-sided tests procedure to determine whether the average values for the PK measures determined after administration of T and R were comparable. This approach is termed average BE and involves the calculation of a 90 percent confidence interval for the ratio of the averages (population geometric means) of the PK measures for T and R. To establish BE, the calculated confidence interval should fall within a BE limit, usually 80.00 percent to 125.00 percent for the ratio of the product averages.6 In addition to this general approach, the 1992 guidance provided specific recommendations for (1) logarithmic transformation of PK data, (2) methods to evaluate sequence effects, and (3) methods to evaluate outlier data.
In addition to reiterating the key points from the 1992 guidance and replacing that guidance, the 2001 guidance introduced two additional approaches to assessing BE: population BE and individual BE. Both of these approaches, unlike the average BE approach, include a comparison of the variabilities of the PK metrics of the two products being compared, as well as the average responses. However, the individual BE approach is not currently used in the regulatory setting, while the population BE approach is mainly used for certain in vitro BE studies when variability as well as means need to be compared for clinical reasons. The 2001 guidance also included discussion of replicate crossover designs, which involve the administration of at least one of the products to at least some of the subjects more than once. The discussion of these designs in that guidance included their implications for possible carryover effects and their use in screening for outliers.
This guidance provides recommendations on the topics covered by the 1992 guidance and the 2001 guidance, as well as recommendations on some additional topics. As noted in the Introduction section above, this guidance replaces the 2001 guidance.
II. GENERAL CONSIDERATIONS
A. Study Design
1. Experimental Design
Various experimental designs can be used to establish BE. For most BE studies, the typical experimental design is a nonreplicate design (see section II.A.1.a, Nonreplicate designs). For highly variable drugs (see section III.C, Statistical Methods for Highly Variable Drugs) or NTI drug products (see section III.B, Statistical Methods for Narrow Therapeutic Index Drugs), a replicate crossover design (see section II.A.1.b, Replicate crossover designs) is often used. When applicants are uncertain about study design parameters, such as the variability of the PK parameters or comparative clinical endpoint, an adaptive design (see section II.A.1.c, Adaptive design) may be appropriate. In studies where sampling can only be done at a single time point or limited number of time points for each subject, a sparse design (see section II.A.1.d, Design with sparse sampling) may be appropriate. In these last two cases, the underlying experimental design can be either a crossover or parallel group design.
a.Nonreplicate designs
two-period, two-sequence crossover design, commonly referred to as a two-way crossover design, can be used to generate data when an average or population approach is chosen for BE comparisons. Under certain circumstances, such as products with apparent, long half-lives, where crossover designs are impractical, parallel designs can be used.
b. Replicate crossover designs
A replicate crossover study design (either partial or fully replicate) is appropriate for drugs regardless of whether the reference is a highly variable drug or not. A replicate design can have the advantage of using fewer subjects compared to a nonreplicate design, although each subject in a replicate design would receive more treatments.
Further, a replicate design is recommended to be used under the following scenarios:
A replicate design is advantageous over a nonreplicate design for non-NTI drugs with a high within-subject variability in at least one of the PK measures. Either a partial or fully replicate design can be used in this scenario, but the reference-scaled average BE analysis approach should only be applied to specific PK metrics that exhibit a high within-subject variability for the reference in the pivotal BE study.
A fully replicate design is recommended for NTI drugs, where within-subject variability for both the reference material and test product can be computed and a reference scaled-average BE analysis can be conducted to properly adjust the BE acceptance criteria.
A fully replicate design may be recommended for certain non-NTI drugs when the BE approach includes a comparison of the within-subject variability of the test product and reference material.
Replicate crossover designs can be used irrespective of which BE approach is selected to establish BE, although they are not necessary when an average or population BE approach is used. When a reference-scaled average BE approach is used, replicate crossover designs are critical to allow estimation of within-subject variances of each PK parameter for R (and T if a fully replicate study is used). For BE studies with fully replicate designs, the four-period, twosequence, two-formulation design, commonly referred to as four-way, full-replicate design, shown below, is recommended.
For this design, the same lots of the T and R formulations should be used for the replicate administration. Each period should be separated by an adequate washout period. Other fully replicate crossover designs are also possible. For example, a three-period design, as shown below, could be used. A fully replicate design can estimate the subject-by-formulation interaction variance components.
Original link:https://www.fda.gov/media/163638/download