3.6 Would a specific bioequivalence study with administration of crushed/disintegrated tablets be required for a generic application? March 2019
3.6 If the SmPC of a reference product allows for the possibility to administer a tablet crushed or disintegrated (and mixed with food), would a specific bioequivalence study with administration of crushed/disintegrated tablets (Test and Reference) be required for a generic application? March 2019
Revised PKWP position:
The bioavailability of the active substance(s) may be altered if the product is crushed/disintegrated to assist swallowing and also if a crushed/disintegrated tablet is mixed with food. This potential change in bioavailability may not only be drug-dependent, but also formulation/product-specific dependent in some cases. Therefore, serious concerns arose that a test product shown to be bioequivalent when administered as a whole tablet, might exhibit different bioavailability compared to the reference product when both are administered crushed/disintegrated (and dispersed in food). Consequently, under previous published guidance the expectation was that bioequivalence should also be demonstrated for the additional mode of administration, unless a series of specified criteria could be met, in order to waive additional in-vivo investigations.
However, the PKWP has revised its position on this topic and presently considers that it is highly unlikely that the change in bioavailability will be different between test and reference, once bioequivalence has been shown between test and reference with the intact or non-dispersed tablet.
Consequently, if the SmPC of the reference product allows for the possibility to administer the tablet crushed/disintegrated (and dispersed in food), bioequivalence does not need to be also demonstrated with this additional mode of administration.
For products that could be dispersed in water and administered via a nasogastric tube, in vitro data to support the claimed SmPC-wording should be provided.
3.7 If the test product is an oral solution (or suspension) dosed in single dose sachets and the test product claims the administration with or without water (or makes no claim), how should the test product be administered in the BE study? ... Sept 2017
If the test product is an oral solution (or suspension) dosed in single dose sachets and the test product claims the administration with or without water (or makes no claim), how should the test product be administered in the BE study - with or without concomitant fluid intake? If the test product is an oral powder or granulate dosed in a single dose sachet for intake with or without water it is understood that it should be assimilated to an orodispersible tablet, orodispersible film, buccal tablet or film, sublingual tablet or chewable tablet, but how should oral solutions/suspensions be tested? September 2017
The requirements for the investigation of bioequivalence/comparative bioavailability for oral solutions and suspensions regarding fluid intake during administration can be summarised as follows:
1.In case the SmPC of the reference product states that it should be administered with water and the test product claims the same then during the study both products should be administered with water.
2.In case the SmPC of the reference product states that the product should be administered without water and the test product claims the same then during the study both products should be administered without water.
3.In case the SmPC of the reference product states that it should be administered with water and the test product claims that it can be administered both with or without water then during the study both products should be administered with water and additional data for the test product without water (e.g. a third study arm) should be submitted to support this claim.
4.In case the SmPC of the reference product states that it should be administered with or without water and the test product claims the same then during the study both products should be administered without water as this generally represents “the worst-case scenario”.
In case the SmPC of the reference product states nothing concerning fluid administration and the test product claims the same then during the study both products should be administered without water as this generally represents “the worst-case scenario”.
Rationale:
Changing the volume of fluid intake can affect the gastrointestinal transit time and in certain cases the in vivo solubility of the active substance and/or the concentration of a critical excipient and hence the absorption of the active substance. Therefore, a possible effect of fluid intake during administration on the bioavailability of an oral solution/suspension cannot be excluded. As the magnitude of this effect is expected to be maximal when administration takes place without water, which generally represents the worst-case scenario, it would be preferable to investigate bioequivalence/comparative bioavailability under these conditions. Deviations from this approach should be scientifically justified and supported by additional study data and/or literature.
3.8 What are the recommendations for a biowaiver of an additional strength for gastro-resistant preparations (e.g. omeprazole)? July 2010, March 2018 (updated April 2018) and May 2020
The general requirements for biowaiver of an additional strength are detailed in section 6.2.2. of the Guideline on the pharmacokinetic and clinical evaluation of modified release dosage forms (Guideline on the pharmacokinetic and clinical evaluation of modified-release dosage forms).
The dissolution profiles should be compared not only in Pharmacopoeial conditions (2 hours at pH 1.2 followed by 45 minutes at pH 6.8), but also at more neutral pHs in the range 2-5, both for single unit non disintegrating and disintegrating dosage forms with multiple units. Hence, at least, two dissolution tests in two steps are required. First, a comparison at pharmacopoeial conditions, 2 hours at pH 1.2 followed by 45 minutes in pH 6.8 and then, a second separate dissolution test at a higher initial pH mimicking fed state, e.g. 2 hours at 4.5 followed by 45 minutes in pH 6.8.
Concluding similarity if dissolution of more than 85% is obtained within 15 minutes is not applicable for gastro-resistant formulations. In case of gastro-resistant formulations the release occurs after gastric emptying (median approx. 13-15 min). Therefore, the comparison of dissolution profiles should be performed even if dissolution is more than 85% before 15 min in either products or strengths. Hence, a tight sampling schedule is recommended after the product has been investigated for 2 hours in media mimicking the gastric environment (pH 1.2 or 4.5) since profile comparison (e.g. using the f2 calculation) is required.
3.9 Is the Mahalanobis Distance (MD) an adequate measure for use in the assessment of dissolution similarity, in particular in cases where the f2 statistic is not suitable? Can interval estimation be used to inform decision... (superseded/incorporated)
Is the Mahalanobis Distance (MD) an adequate measure for use in the assessment of dissolution similarity, in particular in cases where the f2 statistic is not suitable?
Can interval estimation be used to inform decision making for the similarity of dissolution profiles based on an inferential statistical approach (with MD or other statistical measures)?
As background to the comments provided below, it is considered important to note that in cases when f2 is considered suitable, i.e. can be used as outlined in Appendix 1 of the CHMP guideline on the investigation of bioequivalence [CPMP/EWP/QWP/1401/98 Rev. 1/ Corr **], guideline-compliant evaluation of dissolution similarity does not involve confidence interval estimation to decide upon similarity. The recommended decision criterion is based only upon the derived numerical value for f2 (point estimate ≥ 50)1. This means that the uncertainty related to the f2 sampling distribution is not accounted for. Against this background, the question concerning an adequate alternative statistical decision criterion, for cases where f2 should not be used, is difficult to answer. Some of the recently suggested alternative statistical approaches to measure the distance between two dissolution profiles involve an inferential element, i.e. the estimation of a confidence interval or region. Since f2 employed on its own does not have any inferential element, comparing these potential alternatives to the standard f2 criterion is hence not straightforward.
Regarding the MD, it is a dissimilarity measure between two random vectors x and y of the same length, which takes into account the correlations in the data set. MD is the multi-dimensional generalisation of the idea of expressing the distance between two points using standard deviation as the unit of measurement. This standardisation means that MD is dependent on variance and covariance estimates. In dissolution data sets, covariates generally correspond to dissolution percentages collected for different time-points. Under some assumptions, the MD becomes smaller, indicating similar dissolution profiles, with increasing variability observed in the data. This property makes its use undesirable for deciding upon similarity in dissolution, in particular with regard to the additional criterion that similarity limits should not be greater than a 10% difference at any time point is satisfied [CPMP/EWP/QWP/1401/98 Rev. 1/ Corr **]; depending on the variability observed it is quite possible to have an observed difference of over 10% at some time point, yet MD-based criteria could declare the difference to be unimportant.
Based on these considerations, the MD metric cannot be supported as a preferred methodological approach to decide upon similar dissolution, even in situations where the f2 statistic should not be used in the way outlined in the CHMP bioequivalence guideline.
Any approach based upon confidence intervals for f2 would, however, be considered appropriate whether the validity criteria outlined in CHMP guidance are met or not [CPMP/EWP/QWP/1401/98 Rev. 1/ Corr **]. Similarity could then be declared if the confidence interval for f2 were entirely above 50. However, regardless of whether the conditions to adequately apply f2 in a dissolution experiment are fulfilled or not, the properties of the f2 sampling distribution do not allow the derivation of exact confidence intervals to adequately quantify the uncertainty of the f2 estimate. To address this, bootstrap methodology could be used to derive confidence intervals for f2 based on quantiles of re- sampling distributions, and this approach could actually be considered the preferred method over f2 and MD.
1 Another drawback of the f2 is that neither the shape of the dissolution profiles nor the time correlation is taken into account. Permuting the order of the time points would give the same f2 estimate, provided the time points in the test group are always compared to the same time points in the reference group. This means the f2 metric is not using all potentially relevant information available. Implications of this property on the sensitivity/specificity of the f2 decision criterion remain uncertain.
Source: EMA