3.10 What is the recommendation on what extent of active ingredient that should be released in a comparative local in vivo availability study, in order to allow a conclusion of comparable local exposure for lozenges? March 2020

For products acting locally in the mouth and/or throat, the guideline on equivalence studies for the demonstration of therapeutic equivalence for locally applied, locally acting products in the gastrointestinal tract (CPMP/EWP/239/95 Rev. 1, Corr.1) states that in those cases where it is justified that the drug is released from the dosage form as a solution due to its high solubility, it is possible to assess indirectly the local availability or the amount released by assessing the amount remaining in the dosage form at selected time points in an in vivo study. The guideline does however not mention to what extent the active substance must be released to ensure a conclusive result. 

The PKWP is of the opinion that if equivalence is evaluated with this type of study, the lozenges (test and reference) are expected to be completely dissolved during the study time. Given the limited experience at the current time for this type of in vivo study, the PKWP considers that a recovery of >85% is expected, unless otherwise justified.  

When the study is designed, consider providing an instruction to the subjects on how to suck the lozenge in order to achieve sufficient release during a reasonable study time. 

 

3.11 Expectations for bootstrapping to calculate the 90% confidence interval for the f2 similarity factor - (superseded/incorporated into Q & A 3.13 August 2023)

Introduction

Appendix I of the Guideline on the Investigation of Bioequivalence defines the f2 similarity factor as the method for testing the similarity of dissolution profiles as well as the conditions where it is not necessary (i.e. when more than 85% is dissolved in 15 min in oral products for systemic action) and the requirements for its calculation (i.e.

a minimum of three time points (zero excluded),

the time points should be the same for the two formulations,

at least twelve individual values for every time point for each formulation,

not more than one mean value of > 85% dissolved for any of the formulations and

the relative standard deviation or coefficient of variation of any product should be less than 20% for the first time point and less than 10% from second to last time point).

This last requirement has been slightly modified in the ‘Reflection paper on the dissolution specification for generic solid oral immediate release products with systemic action’, where high variability of the dissolution results have been exemplified as > 20% RSD at time-points ≤ 10 minutes, > 10% RSD in the later phase for a sample size of 12. Similarly, in the ICH M9 Guideline on Biopharmaceutics Classification System-based Biowaivers, it is stated: “To allow the use of mean data, the coefficient of variation should not be more than 20% at early time-points (up to 10 minutes), and should not be more than 10% at other time points”. A tendency to avoid early sampling times (e.g. at 5 min) has been observed, which might cause an incomplete characterisation of the profile, to avoid excessive variability in more than one sampling time (e.g. at 5 and 10 min). Therefore, this modification should be taken into account. Furthermore, all sampling times pre-defined in the dissolution study protocol until the sampling time where one of the products reaches > 85% dissolved should be considered in f2calculation. The dissolution study protocol should indicate the study objectives, pre-specify the batches to be compared, the dissolution test conditions (apparatus, media composition, agitation rate), media de-aeration, sample filtration and analytical methodology, sampling approach, sampling times, and include the full description of methodology employed for dissolution profile comparison (e.g. f2 if variability conditions are met and bootstrap 90% CI of expected f2 with a percentile method for bootstrap 90% CI calculation if variability conditions are not met, including software to be used, number of bootstrap samples, seeds, etc.).

Appendix I of the Guideline on the Investigation of Bioequivalence indicates that when the f2 statistic is not suitable, then the similarity may be compared using model-dependent or model-independent methods e.g. by statistical multivariate comparison of the parameters of the Weibull function or the percentage dissolved at different time points. Alternative methods to the f2 statistic to demonstrate dissolution similarity are considered acceptable, if statistically valid and satisfactorily justified. However, PKWP/BSWP Question and Answer 3.9 clarified that “the Mahalanobis Distance (MD) metric cannot be supported as a preferred methodological approach to decide upon similar dissolution, even in situations where the f2 statistic should not be used in the way outlined in the CHMP bioequivalence guideline. Any approach based upon confidence intervals for f2 would, however, be considered appropriate whether the validity criteria outlined in CHMP guidance are met or not. Similarity could then be declared if the confidence interval for f2 were entirely above 50. However, regardless of whether the conditions to adequately apply f2 in a dissolution experiment are fulfilled or not, the properties of the f2 sampling distribution do not allow the derivation of exact confidence intervals to adequately quantify the uncertainty of the f2 estimate. To address this, bootstrap methodology could be used to derive confidence intervals for f2 based on quantiles of re-sampling distributions, and this approach could actually be considered the preferred method over f2 and MD”.

This Q&A describes expectations for conducting and reporting bootstrap methodology.

Bootstrap methodology

The use of two-sided 90% confidence interval of f2 is the recommended methodology for dissolution comparison when highly variable conditions occur, since the use of f2 could be highly influenced by the experimental dissolution data and might not represent the population (true) f2.

The bootstrap analysis should be performed using at least 5,000 samples and the number of samples should be reported. The calculation of the 90% confidence interval should be conducted using any of the percentile methods described by Hyndman and Fan [1]. All sampling times pre-defined in the dissolution study protocol should be considered in the calculation until the sampling time where one of the products reaches >85% dissolved should be considered in the bootstrap dissolution samples.

The estimation of the f2 value on each bootstrapped dissolution sample should be performed using the Expected-f2 formula [2]. Equation 1 summarises the mathematical description of the Expected-f2:

Clinical pharmacology and pharmacokinetics: questions and answers Part4

Reporting of study results

When reporting dissolution profile comparisons, the applicant should provide individual results of the percentage dissolved at the different sampling times pre-defined in the protocol as well as mean percentage dissolved with its variability (CV(%)) in order to allow the replication of the calculations.

In addition, the applicant should discuss the basis for the similarity conclusion: dissolution is > 85% in 15 min for oral products with systemic action, f2 similarity factor calculation (e.g. acceptable variability, no more than one sampling time above 85% dissolved, etc.) is needed, or if the 90% confidence interval of f2 is required.

In case of bootstrapping, similarity in dissolution profiles will be concluded when the lower limit of the 90% confidence interval for the Expected f2 is ≥ 50. The results should be reported rounded to the nearest integer without decimal units.

Software packages

Specific software packages for the calculation of the 90% confidence interval of f2,EXP or in-house platforms could be used. In any case, the software should be adequately documented. In the case of specific software packages, the selected options (e.g. whole vectors, one profile, number of bootstrap samples, seed number, if available) should be described. In the case of in-house platforms, the code of the platform should be provided and it should be demonstrated that the employed software is able to calculate the 90% confidence interval of f2,EXP correctly. See [3] for examples of datasets and results.

References:

R.J. Hyndman, Y. Fan. Sample quantiles in statistical packages. The American Statistician. 50 (1996) 361–365.
https://doi.org/10.1080/00031305.1996.10473566

M.-C. Ma, B.B.C. Wang, J.-P. Liu, Y. Tsong. Assessment of similarity between dissolution profiles., J Biopharm Stat. 10 (2000) 229–249. https://doi.org/10.1081/BIP-100101024.

L. Noce, L. Gwaza, V. Mangas-Sanjuan, A. Garcia-Arieta. Comparison of free software platforms for the calculation of the 90% confidence interval of f2similarity factor by bootstrap analysis. Eur J Pharm Sci. 2020;146:105259.https://doi.org/10.1016/j.ejps.2020.105259.

 

3.12 Clarification on guideline requirements for parenteral oily solutions - December 2022

Clarification on Appendix II of the Guideline on the investigation of bioequivalence  (CPMP/EWP/QWP/1401/98 Rev.1/Corr**) on whether viscosity and/or other in vitro comparative data are needed to demonstrate comparable physicochemical characteristics of oily solutions, sufficient to support a biowaiver.

Appendix II of the Guideline on the investigation of bioequivalence (CPMP/EWP/QWP/1401/98 Rev. 1/ Corr **) contains the following paragraph for parenteral solutions:

In the case of other parenteral routes, e.g. intramuscular or subcutaneous, and when the test product is of the same type of solution (aqueous or oily), contains the same concentration of the same active substance and the same excipients in similar amounts as the medicinal product currently approved, bioequivalence studies are not required. Moreover, a bioequivalence study is not required for an aqueous parenteral solution with comparable excipients in similar amounts, if it can be demonstrated that the excipients have no impact on the viscosity.

As a crucial prerequisite, it is clarified that the text of the bioequivalence guideline for an oily solution with a route of administration different to intravenous, e.g. intramuscular or subcutaneous, implicitly refers to the use of the same oil as excipient, i.e. vehicle of test and reference product.

For oily parenteral solutions that contain the same excipients in similar amounts, a bioequivalence study is not required if the test drug product’s 'rheological behaviour' (e.g. viscosity but not exclusively) and other physicochemical properties (e.g. partition coefficient and injectability) are equivalent to those of the reference product. For demonstration of equivalence, it is recommended to apply inferential statistical methodology with the commonly used equivalence criteria (90% confidence interval, 5% significance level).

Depending on the type of reference product, batches may exhibit higher variabilities. It is advised to perform the equivalence studies on the basis of data from pilot/development studies, which have investigated the variability of the reference product (using an adequate number of batches). The equivalence studies should be conducted with ‘a priori’ determined criteria and using other batches than those used in the pilot/development studies.

Reference is made to the Reflection paper on statistical methodology for the comparative assessment of quality attributes in drug development (EMA/CHMP/138502/2017).

Other excipients such as antioxidants, preservatives and buffers, that are used in small amounts, may be qualitatively and/or quantitatively different from those used in the reference product. This may be acceptable, if these changes are adequately justified and if it can be demonstrated that these differences do not have an impact on the 'rheological behaviour'. Apart from viscosity, other physicochemical properties like the partition coefficient and injectability may also need to be considered, if these excipients differ.

One important aspect of oil as a vehicle that is not an issue for an aqueous vehicle is that the Ph. Eur specification for a certain oil may allow a difference in fatty acid composition, e.g. the Ph. Eur specification for castor oil allows wide variability of fatty acid composition and castor oil exists in different qualities, up to “super refined”.

Given a different fatty acid composition may result in a different release of the drug from the formulation, for oily solutions with differences in fatty acid composition a bioequivalence study is needed unless the test product’s 'rheological behaviour' is equivalent to that of the reference product. 

So, even if the excipients are the same for the test and reference product, a suitable specification of the test product should be set in accordance with the 'rheological behaviour' results of the reference product.

Comparability in fatty acid composition is also relevant in the context of storage time because a different oxidative alteration (gumming-up) of the fatty acids could result in altered 'rheological behaviour', e.g. (higher) viscosity. Therefore, any differences in fatty acid composition should be justified and it should additionally be demonstrated that there is no impact on the 'rheological behaviour' of the product during its shelf-life.

For all other differences in composition or where the 'rheological behaviour' of the oily parenteral solution is not equivalent, in vivo bioequivalence studies are necessary to demonstrate that there is no impact on the bioavailability of the active substance. In addition, the safety and tolerability of the test product may need to be addressed if the oily vehicle or co-solvents are changed.