Adjustment to chromatographic separations test procedures as per Ph. Eur. general chapter 2.2.46
Introductory note:
This Q&A provides information on how Ph. Eur. general chapter 2.2.46 Chromatographic separation techniques (in particular with respect to the adjustment of chromatographic conditions) can be used for non-compendial (in house) analytical procedures and when the conditions described in the pharmacopoeia text apply.
Background information:
When a pharmacopoeial test procedure is used as intended, the test procedure is not required to be described in the dossier. Instead a cross-reference to the current respective Ph. Eur. monograph is considered sufficient.
A pharmacopeial test procedure adjusted within the limits prescribed in Ph. Eur. general chapter 2.2.46 Chromatographic separation techniques is considered to be the pharmacopeial test procedure.
In all other cases, the test procedure is considered to be an in-house test procedure. This means that the full description of the test procedure and validation data should be provided in the dossier.
Expand sectionCollapse section
1. Should a variation application be submitted in case of adjustments to chromatographic parameters of an analytical test procedure, when the adjustments introduced are within the limits prescribed in Ph. Eur. general chapter 2.2.46?
a) If the applicant is using the pharmacopoeial test procedure as described in the respective monograph
No, a variation application is not necessary.
b)If the applicant is using an in-house test procedure for the finished product, that is based on the one described in the respective monograph of the active substance
Yes, a variation must be submitted according to the relevant variation guidance and the relevant documentation should be provided.
C) If the applicant is using an in-house test procedure for the active substance/finished product/excipient (regardless of whether reference to the corresponding Ph. Eur. general chapter(s) is made)
Yes, a variation must be submitted according to the relevant variation guidance and the relevant documentation should be provided.
2. If yes, how should such variations be classified?
Where an adjustment of chromatographic test parameter(s) is made to a non-compendial (in-house) test procedure, within the limits and conditions defined in Ph. Eur. general chapter 2.2.46, it is considered that the method of analysis remains the same. The analytical procedure description in the dossier should be updated accordingly. The change can be notified to the competent authority as a minor Type IA variation (for veterinary medicines: variation not requiring assessment (VNRA)) under the relevant classification category.
Where an adjustment of chromatographic test parameter(s) is made to a non-compendial (in-house) test procedure outside the limits and conditions defined in Ph. Eur. general chapter 2.2.46, it is considered that the method of analysis has changed. The analytical procedure description in the dossier should be updated accordingly. The change can be submitted to the competent authority as a minor Type IB variation (for veterinary medicines: variation requiring assessment) under the relevant classification category.
3. Is method revalidation required in case of adjustments to chromatographic parameters of an in-house analytical procedure, when the adjustments introduced are within the limits and conditions prescribed in Ph. Eur. general chapter 2.2.46?
General chapter 2.2.46 describes the extent to which various parameters of a chromatographic test procedure, as described in an individual monograph, may be adjusted without fundamentally modifying the pharmacopoeial analytical procedure.
The same principles as those described in Ph. Eur. 2.2.46 may also be applied in case of adjustments to chromatographic parameters of non-compendial (in-house) analytical procedures.
Adjustments other than those indicated in Ph. Eur. 2.2.46 require revalidation of the test procedure.
4. To meet the conditions for a Type IA variation / VNRA, what are “appropriate validation studies” to show that the updated test procedure is at least equivalent to the former test procedure?
If the adjustment has been performed within the limits and conditions described in Ph. Eur. general chapter 2.2.46, compliance with system suitability test (SST) criteria and other conditions described in the chapter (e.g. selectivity and elution order of any specified impurities should be equivalent) is considered sufficient to show that the updated test procedure is at least equivalent to the former test procedure. In this case, further validation of the test procedure is not deemed necessary.
An SST covering the relevant critical analytical procedure attributes should be described in the dossier. After adjustment of an analytical procedure, it should be considered whether the SST requirements are still adequate and sufficient for the adjusted analytical procedure.
Change in the appearance of tablets during storage
1. (When) is a change in the appearance of an oral medicinal product during its shelf life considered acceptable? H July 2013
Is the submission of data regarding manufacturing process validation, analytical validation, and stability studies, produced only by the developer of the product sufficient? Does it make any difference if the developer of the product is presented as one of the product manufacturers or not? H+V July 2008
These questions and answers only concern products that are oral solid dosage forms manufactured by standard manufacturing methods. The new product has the same formula and manufacturing method of the developed product.
Provided that the formula, manufacturing process, analytical methods and packaging materials are the same, data originating from the developer of the product is normally sufficient. As regards manufacturing process validation, the marketing authorisation holder, according to the Note for guidance on process validation, must submit with the new application the process validation scheme and the commitment to carry out process validation and initiate stability studies along with the batch analysis for production scale batches for the new manufacturing site. This is irrespective of whether the product developer is one of the manufacturing sites of the new product or not.
2. Who is responsible to verify the production scale validation data when this is available? H+V July 2008
These questions and answers only concern products that are oral solid dosage forms manufactured by standard manufacturing methods. The new product has the same formula and manufacturing method of the developed product.
According to the Note for guidance on process validation, "the results can be subsequently verified by supervising authority according to national procedure.” Depending on the product and the concerns that may arise, in some countries this may be dealt with as a post-authorisation commitment or it may be brought to the attention of good-manufacturing-practice inspectors to be checked during their next inspection.
The marketing-authorisation holder is usually not expected to present these data with the new application, unless it is requested by the licensing authorities.
3. Can the test product of a bioequivalence study be produced by the developer, irrespective of whether that developer is one of the manufacturing sites of the new product? H+V July 2008
These questions and answers only concern products that are oral solid dosage forms manufactured by standard manufacturing methods. The new product has the same formula and manufacturing method of the developed product.
The product used in the bioequivalence study must be representative of the industrial scale product to be marketed.
A bioequivalence study conducted using a test product produced by the developer is acceptable if the developer is also one of the manufacturers of the new product.
If the developer is not one of the manufacturers of the new product, it has to be demonstrated that the bioequivalence batch is representative of the industrial scale product to be marketed.
For this the following applies:
The developer product and the new product must have identical formula, specifications, manufacturing process and equipment;
The active substance supplier is the same or it is ensured that characteristics of the active substance that may have an impact on the bioavailability are identical;
The excipients characteristics which may have an impact on the bioavailability of the active substance are identical;
The dissolution profiles of batches produced by the developer (including the biobatch) and the product from the new manufacturer (at least pilot batches) must be similar;
Comparative pilot batch analysis between the developer product (including the biobatch) and the new manufacturer product must be presented.
4. Is there any requirement for the marketing-authorisation holder to submit any kind of proof (e.g. statement or contract) that it has obtained the dossier from the developer legally? H+V July 2008
These questions and answers only concern products that are oral solid dosage forms manufactured by standard manufacturing methods. The new product has the same formula and manufacturing method of the developed product.
No such proof is necessary to be presented in the application dossier.
European Pharmacopeia (Ph. Eur.) - Harmonised Ph. Eur. Chapters 2.6.12, 2.6.13 and 5.1.4
1. How should any update to the microbial quality control of a finished product be achieved? H+V February 2012
How should any update to the microbial quality control of a finished product, specifically linked to the update to the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) harmonised Ph. Eur. methods (2.6.12 and 2.6.13) and limits (5.1.4) be achieved? H+V February 2012
Any changes to implement the harmonised methods (2.6.12 and 2.6.13) should be submitted under change code B.II.d.2.a (type IA).
Any changes to implement the harmonised limits (5.1.4) should be submitted as follows:
Changes to the limits – B.II.d.1.a (type IA), but only in the following situations:
The currently registered microbial control limits (present situation) are totally in line with the pre-January 2008 (non-harmonised) situation and did not include any additional specified controls over and above the Pharmacopoeia requirements for that particular dosage form. In addition, the proposed controls are totally in line with the harmonised monograph.
If for any reason these criteria are not met, a type IB variation (B.II.d.1.z) should be submitted.
In accordance with current requirements, any changes should be clearly identified (present / proposed) in the variation submission and the affected parts of the marketing-authorisation dossier should be appropriately updated, including a description of how the method is applied to the specific product.
Please note that this advice supersedes the questions and answers dated August 2007, which are now out of date.
European Pharmacopeia - Monograph on tablets
1. How should industry apply the revised test subdivision of tablets in the European Pharmacopeia monograph on tablets? H+V October 2006
European Pharmacopeia - Monograph on tablets
1. How should industry apply the revised test subdivision of tablets in the European Pharmacopeia monograph on tablets? H+V October 2006
The requirements of the European Pharmacopoeia (Ph. Eur.) general monograph on tablets for tablets with one or more breaklines have been revised as of 1 July 2006. The previous version of the monograph, which has been in force since April 2002, requested compliance with either test A (uniformity of content of single-dose preparations) or the test for uniformity of mass of single-dose preparations. It did not, however, give any information on how to select the parts to be tested. Supplement 5.5 now provides background information on the use of breakmarks and describes the sampling procedure and the number of tablet parts to be tested in detail. As a test procedure, it prescribes determining uniformity of mass, while setting the somewhat wider acceptance criteria of the test of content uniformity, namely 85 - 115% (in this case of the average mass).
According to Directives 2001/83/EC and 2001/82/EC, the monographs of the Ph. Eur. are the official standards of appropriate quality in the marketing authorisation procedures. In the pharmacopoeia it is also stated that a preparation must comply with the monograph throughout its period of validity.
As the revised text defines lesser requirements with wider acceptance criteria than the previous version (see above), a decision has been taken by the regulatory authorities of the European Union (EU) that the revised test on subdivision of tablets is to be applied to all new applications for marketing authorisations as well as all existing products. It is acknowledged, however, that the new test will not have been applied to products which are in the final stages of their development. In order not to delay any immediate applications and in line with the period of time defined in the variations regulation, a transitional period of 6 months following the coming into force of Ph. Eur. 5.5 has been defined, in which the EU regulatory authorities will accept submission of results which have been generated using the previous version of the monograph.
As the requirements on subdivision of tablets are listed in the production section of the general monograph on tablets, it will normally be sufficient to perform the test only in the framework of pharmaceutical development. There is no need to include the test in the release specification. However, in situations where there is a significant change in tablet hardness during storage, it may be necessary to repeat the test at the end of shelf-life in order to ensure that the scorability has not changed as a function of hardness.
Source: EMA