The Committee for Medicinal Products for Human Use (CHMP) may seek the input of the Methodology Working Party (MWP) to address specific questions in relation to clinical pharmacology and pharmacokinetics. This input may contain general guidance or clarify specific aspects of scientific guidelines and product-specific bioequivalence guidance.
The date after each question refers to when it was first published. Several Q&As refer to the PKWP (Pharmacokinetics Working Party), whose activities have been taken over in 2022 by the MWP.
1. Pharmacokinetics
1.1 What does the Agency recommend on the determination of absolute and relative bioavailability? January 2011
Absolute bioavailability
Information on absolute bioavailability is important in the overall evaluation of the pharmacokinetics of the drug substance. For some new chemical entities information on absolute bioavailability facilitates the evaluation of the mass balance study, and enables conclusions regarding the contribution of different elimination routes to drug clearance.
This information is important when determining the need for studies in subjects with renal and hepatic impairment as well as the need for drug-drug interaction studies at biliary excretion level. The information is also useful when predicting the consequences of pre-systemic drug-drug interactions, both at absorption and metabolism level.
Therefore, for new active substances intended for systemic action, the absolute bioavailability should, if possible, be determined by comparing the bioavailability of the intended pharmaceutical form for an extra-vascular route of administration with an intravenous administration. For substances with non-linear pharmacokinetics, consideration should be given to the dose(s) used for evaluation of absolute bioavailability. Furthermore, data on absolute bioavailability is valuable in the evaluation of BCS based biowaivers (see Guideline on the investigation of bioequivalence, CPMP/EWP/QWP/1401/98 Rev. 1).
Relative bioavailability
It is recommended to obtain information on the relative bioavailability of different dosage forms (or formulations) used during drug development. By definition relative bioavailability is the comparison of different dosage forms (or different formulations thereof) administered by the same or a different non-intravenous route (e.g. tablets vs. oral solution).
Regarding formulation changes during drug development, unless BCS based biowaiver is applicable bioequivalence studies are needed if there has been a change between the formulation used in phase III and the final marketing formulation which may affect rate or extent of absorption. Relative bioavailability studies (or comparative bioavailability studies) are recommended between different formulations used during phase I, II and III. There is no requirement for demonstration of bioequivalence between phase II and phase III formulations. It is assumed that any difference in rate or extent of absorption between these formulations is taken into account in the design of the phase III studies.
The clinical relevance of any differences in exposure between formulations used in phase I, II and III studies should be discussed in applications for NCEs in Module 2.5 and 2.7.1 and taken into account in the assessment of pharmacokinetic data in Module 2.7.2.
1.2 Are there any particular recommendations on the determination of absolute and relative bioavailability for suprabioavailable products? January 2011
A suprabioavailable product displays appreciably larger extent of absorption than an approved reference medicinal product.
If suprabioavailability is found, the development of a lower dosage strength should be considered. In this case, the biopharmaceutical development should be reported and a final comparative bioavailability study comparing the reformulated new product with the approved reference medicinal product should be submitted. The potential for a difference in food effect on the rate and/or extent of absorption or a difference in absorption interactions between the reformulated new product and the approved reference product should be discussed and when relevant evaluated in vivo.
In the case where a lower dosage strength has not been developed the dosage recommendations for the suprabioavailable product will have to be supported by clinical studies.
1.3 Regarding the requirement to perform incurred sample reanalysis (ISR), how should the absence of ISR be handled? December 2012
Regarding the requirement to perform incurred sample reanalysis (ISR), how should the absence of ISR be handled? Is it possible to identify other factors which could be assessed in the absence of ISR to support the validity of the analytical method?
ISR is considered an element of the validation of the analytical method during study sample analysis. It has been discussed for many years in the scientific community and recently been introduced as regulatory requirement in the European guideline. Like for any deviation from a guideline requirement, the lack of ISR requires a scientific justification by the applicant. Such justification could be considered for validations which have been performed before the new guideline came into force. Its scientific validity will need to be reviewed on a case-by-case basis in the light of the overall validation data, the study outcome, as well as the reliance of the application on these data.
Introduction of ISR as a regulatory requirement
The principles for the implementation of a guideline are outlined in the Procedure for European Union guidelines and related documents within the pharmaceutical legislative framework (EMEA/P/24143/2004 Rev.1). While applicants may, with the agreement of the competent authority concerned, choose to apply a guideline in advance of the date for coming into operation of a guideline, competent authorities should await this date before requiring a guideline to be taken into account for assessments. The Guideline on bioanalytical method validation came into force on 1 February 2012 meaning that as of this date this document sets the applicable requirements for the regulatory review of applications.
It is acknowledged in the above-mentioned principles that in some circumstances it may not be possible for applicants to fully comply with new guidelines within this timeframe (e.g. data generated from trials started before the implementation of the new guideline). In such cases, the applicant should consider whether departure from the new guideline could be justified. The applicant's justification will then be considered on a case-by-case basis by the relevant competent regulatory authorities.
In compliance with this framework, the regulatory assessment requires the review of the bioanalytical method validation in any application against the current regulatory standards as set out in the guideline, including the requirement to address incurred sample reanalysis. If an element of the validation is missing, e.g. lack of incurred sample reanalysis, then this would need to be scientifically justified by the applicant. Such justification can be considered in the framework of the above exception that a particular validation has been performed before the bioanalytical guideline came into force, i.e. February 2012. Any justification will need to be reviewed on a case-by-case basis considering the overall validation data, the study results, as well as the reliance of the application on these data.
Considerations regarding a potential justification for the lack of ISR data
The attempt to scientifically justify the lack of ISR is considered only appropriate for the very practical reason that a study was performed before the Guideline on Bioanalytical Method Validation came into force.
For the scientific justification of the lack of ISR the applicant should take all the following points into consideration:
metabolite back conversion:
The applicant should support that back conversion is not an issue for the drug compound or that the risk of back conversion on the outcome of the study results is low as for instance it is known that the drug compound is (almost) not metabolised. For drug compounds for which it is known that back conversion is an issue, i.e. clopidogrel, atorvastatin, ramipril, lack of ISR is considered not acceptable.
other ISR data obtained in the same laboratory:
ISR data obtained for the same analyte from other studies carried out in the same laboratory and with the same analytical method may be used as supportive data to justify the lack of ISR.
data from repeat analysis:
In most studies repeat analysis of study samples has to be carried out for different reasons. Repeat analysis can be considered as ISR in certain situations, however due to the nature of the reanalysis (for instance run acceptance criteria failure) those data are considered not reliable. The applicant should report the data of these reanalysis and take into account and discuss the reason for the reanalysis in the justification for supportive data.
In case of a multi analyte analysis, if the repeat analysis was due to run acceptance criteria failure for one of the analytes, but the other has passed, the results of the analyte(s) which passed can be used to infer ISR, if analysed.
the obtained pharmacokinetic data in the study:
The applicant should compare the obtained pharmacokinetic data with data obtained previously or with reported data and should show that these are comparable
90% confidence interval:
As one element of such justification, if applicable, the applicant could also take into consideration the width of the 90% confidence interval and the ratio to possibly justify that a false positive outcome due to ISR problems has a low probability.
The last two bullet points need to be thoroughly discussed specifically for bioequivalence studies.
The applicant should also consider the overall reliance of the application on the data generated with the bioanalytical method in question.For new molecular entities the pivotal basis of the application normally rests on clinical efficacy and safety studies, nevertheless pharmacokinetic studies in such an application provide significant information (e.g. general pharmacokinetic profile, interactions), which is also reflected in the labelling, hence the validity of such data needs to be sufficiently ensured. Abridged applications may exclusively rely on pharmacokinetic data, e.g. bioequivalence studies, making overall validity of these data paramount. Therefore, the validity of the data needs to be considered for the assessment of the application and the specific study considering whether the data are pivotal or supportive.
Background
The requirement to perform incurred sample reanalysis (ISR) has been introduced with the Guideline on bioanalytical method validation (EMEA/CHMP/EWP/192217/2009). Incurred sample reanalysis (ISR) is applied to assess the reliability of bioanalytical methods used in pre-clinical toxicokinetic studies and for a variety of clinical pharmacology studies including bioavailability, bioequivalence, pharmacokinetic, interaction and comparability studies. The need for incurred sample reanalysis is discussed already since 20061 and regulators supported the need for incurred sample reanalysis also considering significant bioanalytical deficiencies observed in studies. Therefore, although incurred sample reanalysis is a requirement introduced in Europe for the first time with the new EMA Guideline on bioanalytical method validation (EMEA/CHMP/EWP/192217/2009), which came into force in February 2012, it should be noted that the scientific need to perform ISR as an element of bioanalytical method validation was already identified much earlier. ISR should therefore be considered as part of the validation of the analytical method during study sample analysis.
Different sources can be identified which might contribute to the failure of ISR. Some sources may be more likely to occur than other depending on the method, active substance, and analyst, however they cannot be excluded. Sources of ISR failure may be:
Execution, i.e. switched samples, instrument issues, scientist performance of method
Method, i.e. metabolite interferences, back conversion of metabolites, poor ruggedness, internal standard response
Samples, i.e. matrix effects,mislabelling, handling
It is recognized that some of these sources are also likely to occur during validation, like switching samples and mislabelling.
ISR failure and thus lack of the reliability of the study outcome can happen in each study and as such it is difficult to generalise it. Especially with pivotal studies it should be ensured that the results are reliable. However it is also understood that ISR is an additional confirmation of results next to a complete validation.
Source: EMA