Impurities - Residual solvents

 

1. Is there a need to take the actual batch results into consideration whenspecifying class-2 residual solvents for active substances or medicinal products? ^H+V August 2007

 

For class-2 residual solvents in active substances or medicinal products, it is sufficient to restrict the specification to the concentration limit (parts per million) as defined in the notes for guidance on impurities: residual solvents (CPMP/ICH/283/95 EMEA/CVMP/511/03) and related maintenance guidelines or to calculate it based on the respective permitted daily exposure (mg/day) outlined in the guidelines.

It has been agreed by the QWP that there is no need for further tightening of the specification in line with batch results, as the limits in the guideline are based on safety assessment.

 

Manufacture of the medicinal products - Process control

 

1. When validating a manufacturing process, if a common bulk is used to manufacture a series of products, how should the pilot batch size be decided upon? H+V September 2007

 

It is the applicant’s responsibility to select and justify the pilot batch size.

The Note for guidance on process validation states that, “pilot-batch size should correspond to at least 10% of the future industrial scale batch i.e. such that the multiplication factor for scale-up does not exceed 10. For oral solid dosage forms this size should be at least 10% or 100,000 units whichever is greater* unless otherwise justified”.

The guideline does not dictate that the 10% figure should always be linked to the scale of manufacture of individual product presentations. In addition, it allows for departures from the guidance where this is justified. Furthermore, the guideline does not preclude the use of bracketing.

Certain bulk products are used to produce a series of presentations, for example a bulk powder blend may be used to produce 50-mg, 100-mg and 200-mg direct compression tablets with the same percentage composition. In such instances, as long as the applicant can demonstrate a satisfactory link between the pilot batch size used for validation and the routine production batch size, it will usually be acceptable to define the pilot batch size as 10% of the planned production scale for the bulk product. During the process validation study, the complete pilot scale bulk batch should be used to manufacture the individual presentations. The division of the bulk batch between the different presentations should also be justified.

*In the case of veterinary medicinal products, the minimum pilot size may be smaller than 100,000 units where justified.

 

Vancomycin drug products

1. For vancomycin drug products, how should the potency (IU) be declared in the quantitative and qualitative details in the product information? H October 2017

 

By convention, the strength of vancomycin products is stated on labels and prescribed in terms of mass (that is in milligram [mg]) e.g. 500 mg and 1000 mg for IV administration; 125 mg and 250 mg for oral capsules. The product information also includes the quantitative amount of active substance, expressed in international units (IU), i.e. the potency, as determined by microbiological assay.

Historically, the manufacturing formulae and expressions of declared strength have been based on a nominal potency of 1,000 IU/mg. For example, when a dose of 500 mg vancomycin for IV administration was prescribed, then not less than 500,000 IU of vancomycin would be administered.

The potency specified by the European Pharmacopoeia (Ph. Eur.) monograph for vancomycin hydrochloride has changed since the first publication and currently specifies a minimum potency of 1,050 IU/mg. This change has led to discrepancies in the manufacturing formulae and expression of potency in the product information.

To avoid confusion in clinical practice it is essential that the convention of labelling vancomycin products by mass, i.e. mg, is retained. However, to ensure that the established therapeutic dose in terms of IU, e.g. 500,000 IU or 1,000,000 IU, is maintained, the amount (mg) of active substance in the drug product should be adjusted to achieve the declared product strength in terms of IU.

The manufacturing process and batch formulae should be revised where necessary, to achieve the declared content e.g. 500,000 IU or 1,000,000 IU.

To take account of the convention used for vancomycin products, the product information should be expressed as follows:

Vancomycin 500mg powder for concentrate for solution for infusion:

Each vial contains 500mg vancomycin hydrochloride equivalent to 500,000 IU vancomycin.

Vancomycin 1000mg powder for concentrate for solution for infusion:

Each vial contains 1000mg vancomycin hydrochloride equivalent to 1,000,000 IU vancomycin.

Vancomycin 125mg capsule:

Each capsule contains 125mg vancomycin hydrochloride equivalent to 125,000IU vancomycin.

Vancomycin 250mg capsule:

Each capsule contains 250mg vancomycin hydrochloride equivalent to 250,000IU vancomycin.

The product name should remain consistent with prescribing convention as follows:

Vancomycin 500mg powder for concentrate for solution for infusion.

Vancomycin 1000mg powder for concentrate for solution for infusion.

Vancomycin 125mg capsule.

Vancomycin 250mg capsule.

 

Removal of heavy metals tests from a specification - Substances without a Ph. Eur. monograph in existing marketed products

1. Is it necessary to submit a variation when removing a general test for heavy metals from the specification of a substance without a Ph. Eur. monograph in a medicinal product? (H) March 2017

 

Yes. The deletion of a general Heavy metals test from the specification of an ingredient is accepted as a Variation Type 1A. The change does not have to be justified.

 

Removal of heavy metals tests from a specification - Substances with a Ph. Eur. monograph in existing marketed products

Expand sectionCollapse section

1. Is it necessary to submit a variation when removing a general test for heavy metals (Ph. Eur.) from the specification of a substance with a Ph. Eur. monograph in a medicinal product for human use? H+V March 2017

 

No. Reference to the general Heavy metals test (2.4.8) has been deleted in the Ph. Eur. 9.0 from all individual monographs for substances for pharmaceutical use (except those for veterinary use only). Instead the Ph. Eur. General Monograph Substances for Pharmaceutical Use will require that elemental impurities are considered in a risk assessment and the Ph. Eur. General Monograph Pharmaceutical Preparations will make ICH Q3D mandatory for all medicines within the scope of the guideline. Compliance with the revised monographs is an expectation and therefore the deletion of the general Heavy metals test from the specification would not require a variation.

 

2. Is it necessary to submit a variation when removing a general test for heavy metals (Ph.Eur.) from the specification of a substance with a Ph. Eur. monograph in a medicinal product for veterinary use,when the test is removed from the monograph? V 2017

No. Reference to the Heavy metals test (2.4.8) has been deleted in Ph. Eur. 9.0 from all individual monographs for substances for pharmaceutical use (except those for veterinary use only). Instead the Ph. Eur. General Monograph Substances for Pharmaceutical Use will require that elemental impurities are considered in a risk assessment and the Ph. Eur. General Monograph Pharmaceutical Preparations will require elemental impurities to be controlled based on a risk assessment for products outside the scope of Ph. Eur. Chapter 5.20. Compliance with the revised monographs is an expectation and therefore the deletion of the Heavy metals test from the specification would not require a variation.

 

Requirements for selection and justification of starting materials for the manufacture of chemical active substances in veterinary medicinal products

1. For veterinary medicinal products what guidance should be used for the selection and justification of starting materials for the manufacture of chemical active substances? V November 2018

 

A series of questions and answers relating to the guideline on ICH guideline Q11 on the development and manufacture of drug substances became effective in February 2018 (EMA/CHMP/ICH/809509/2016). In order to avoid any potential confusion arising from differences in wording between these questions and answers and the previously existing document 'Requirements for selection and justification of starting materials for the manufacture of chemical active substances' - EMA/CHMP/CVMP/QWP/826771/2016 Corr. 1 , it was agreed that EMA/CHMP/CVMP/QWP/826771/2016 should be replaced by the ICH Q11 questions and answers and EMA/CHMP/CVMP/QWP/826771/2016 is therefore no longer valid. For veterinary medicinal products, the same principles apply and the ICH Q11 questions and answers document EMA/CHMP/ICH/809509/2016 should be consulted for guidance on this topic. Application of this document does not introduce any new requirements but ensures harmonisation and avoids potential confusion.

 

Source: EMA

 

 

HEK293: From Clone Screening to Stable Cell Line Establishment

Cell Factory

EMA Quality of medicines questions and answers: Part 1

Cell Culture Vessels

Related Products

Related News

  • wechat

    Ella: +86 13373342369

Chat with Us