EMA Quality of medicines questions and answers: Part 5

Dec. 09, 2025

Terms ‘granules in capsule for opening’ and ‘oral powder in capsule for opening’

1. When should the terms 'granules in capsule for opening' or 'oral powder in capsule for opening' be used? H November 2024

These standard terms should be used for capsule formulations where only the capsule contents and not the whole capsule should be ingested. The entire contents need to be removed from the capsule before administration, and subsequently administered according to the PI instructions. The administration of only a part of the capsule contents is not allowed. This dosage form is generally intended for those patients unable to swallow the whole capsule, e.g. paediatric and geriatric populations.

The choice of these dosage forms and the administration instructions should be justified by pharmaceutical development data.

For capsules that may be swallowed whole or opened (based on experimental data provided by the applicant) these terms should not be used.

 

2. What additional considerations apply to the terms 'granules in capsule for opening' or 'oral powder in capsule for opening'? H November 2024

Clear administration instructions should be included in the SmPC and in the package leaflet, including pictures. The capsules should be imprinted so that it is obvious to patients and caregivers that capsules need to be opened rather than swallowed whole. A warning should be present on the primary and secondary packaging to inform the patient and caregiver that the capsule should be opened and should not be swallowed.

The ease of opening and emptying the capsules should be demonstrated throughout the proposed shelf life.

For safety reasons (if accidentally swallowed), the capsule should be made from readily digestible materials. Monitoring the safe use of these capsules should form part of the risk management plan.

 

Use of peptones in the manufacture of active substance

1. Is it necessary for the source of any peptone used (e.g. animal or vegetable origin) in the fermentation process for the production of active substances to be included in relevant dossiers? H+V February 2020

Yes. Peptone is considered to be a critical raw material, whose origin (animal or vegetable) and source (supplier name and address) should be specified in any Active Substance Master File (ASMF), Certificate of Suitability (CEP) and where relevant Marketing Authorisation (MA) dossiers. Consequently, if there is any change to the registered information, the change should be sought by appropriate variation (CEP or MA) and for transparency and to ensure relevant responsibilities are adhered to, the change should be immediately communicated to any finished product manufacturer who uses the material.

 

2. Is it necessary for the active substance specifications to declare that fish peptone or fish meal has been used in the manufacturing process and that histamine is a specified impurity controlled to an agreed limit? H+V February 2020

Yes. If fish peptone or fish meal is used in the fermentation process there is a potential serious risk to public health if it is contaminated with high levels of histamine. In order to reduce the risk to public health it is important that the finished product manufacturer is aware that fish peptone or fish meal has been used in the manufacturing process and that histamine is also a specified impurity in the active substance which is controlled to an acceptable limit. 

 

3. What limit for histamine should be applied to gentamicin active substance produced by fermentation used to manufacture parenteral solutions indicated for horses? V September 2025

Histamine in gentamicin active substance has been identified as the root cause of allergic reactions to parenteral solutions administered to horses. In line with the scientific opinion adopted in 2018 by the CVMP under Article 30(3) of Regulation (EC) No. 726/2004, a limit of 8 ppm should be applied to histamine in the gentamicin active substance specification of parenteral solutions for horses. 

 

Variation

1. What is understood by “manufactured by complex manufacturing processes” in change code B.II.b.4 (change in batch size of the finished product) or in change code B.II.b.1 (replacement or addition of a manufacturing site)? V October 2015

In change code B.II.b.4

Complex manufacturing processes is intended to cover situations where the actual manufacture of the finished product involves a process which includes one or more processing steps that may give rise to scale-up difficulties.

 

In change code B.II.b.1

Complex manufacturing processes is, amongst others, intended to cover situations where the link between quality characteristics and in-vivo performance is not fully understood (e.g. nanomedicines).

In both cases these will be considered on a case by case basis.

Where relevant, if a change is submitted as a type IB variation, it is up to the applicant to provide adequate justification for not considering a manufacturing process as a 'complex' one. However, under the safeguard clause, it should be noted that if the supplied justification is not accepted, it is possible for the competent authority to upgrade the submission to a type II variation during the validation phase. If unsure, applicants should consult the relevant competent authority before submitting the variation.

 

Novel or complex manufacturing process in Q.II.b.1 and Q.II.b.4

What is understood by “manufactured by novel or complex manufacturing process” in category Q.II.b.1 (replacement or addition of finished product manufacturing site) and in category Q.II.b.4 (change in batch size of the finished product)? H November 2025

In categories Q.II.b.1 and Q.II.b.4, a "novel or complex manufacturing process" refers to situations where the manufacturing process involves novel or complex technology that may present challenges during site transfer and/or scale-up activities that could impact the quality of the finished product and therefore require submission of type II variations.

It should be noted that not all non-standard processes (as defined in Annex II of the Guideline on process validation for finished products - information and data to be provided in regulatory submissions) are considered complex in this context.

For example, ‘aseptic processing’ is not a complex manufacturing process for the purpose of classifications of changes in categories Q.II.b.1 and Q.II.b.4, but as it is a non-standard manufacturing process, production scale process validation data is required.

Therefore, to help the interpretation of the term "complex manufacturing process" in the categories Q.II.b.1 and Q.II.b.4, some examples of products manufactured by processes that could be considered complex are provided below (but are not limited to):

Advanced Therapy Medicinal Products (ATMPs)

Liposomal preparations

Nanoparticulate preparations (e.g. Lipid nanoparticles)

Parenteral modified release preparations

Metered-dose preparations for inhalation and inhalation powders

Multilayer tablets

In addition, examples of "novel or innovative manufacturing processes" include (but are not limited to):

Continuous manufacturing

Decentralized manufacturing

Additive manufacturing

Use of process models in the control strategy

Manufacture of personalised medicines

Other advanced manufacturing approaches

If a change is submitted as a Type IB variation, applicants must provide a justification if they consider that the manufacturing process is not "novel or complex”, as per the above interpretation. If the justification is not accepted, the competent authority may ask the applicant to withdraw and resubmit as Type II variation. Appropriate variation categorisation can also be anticipated using Post Approval Change Management Protocols. If there is any uncertainty, applicants may consult the relevant authority before submitting the variation.

 