EMA Questions and answers for biological medicinal products(1)

Nov. 28, 2025

This question and answer page is developed and maintained by the CHMP Biologics Working Party (BWP) and provides agreed positions by the Biologics Working Party position on issues that can be subject to different interpretation or require clarification, typically arising from discussions or correspondence during assessment procedures of biological human medicinal products.

 

Storage Sites for Master cell bank/ Working cell bank/ Active substance/ Finished product/ Intermediates (3.2.S.2.1, 3.2.P.3.1)

 

1. Which information should be provided in the dossier for storage sites? October

2024

Storage sites for master cell banks (MCB) and working cell banks (WCB) should be stated in CTD Section 3.2.S.2.1 However, there is no need to register storage sites for active substance/finished product or intermediates in the dossier. For these, only the storage conditions need to be stated in the CTD. 

 

Reprocessing (3.2.S.2.2, 3.2.P.3.3)

 

1.Should reprocessing be explicitly mentioned in the dossier? September 2023

If reprocessing is not mentioned in the dossier, it is assumed it is not applied for. However, Applicants are encouraged to explicitly state in section 3.2.S.2.2 or 3.2.P.3.3 either

at which step(s) reprocessing may be performed. This should be supported by appropriate process validation data,

that there is no reprocessing at any step in the manufacturing process. Reprocessing may be added post-approval through a variation procedure.

 

Raw materials and media components (3.2.S.2.3)

 

1.Should the detailed composition of media components be reflected in thedossier? Rev. June 2025

The applicant/MAH needs to be aware of critical aspects affecting the quality and safety of the biological product, and information on the composition of the media used during manufacturing is required to be included in the dossier for a proper risk assessment regarding possible residual impurities in the finished product. Where media are sourced from an external supplier and quantitative details of the media components are not available, a qualitative composition of media components needs to be provided. A confirmation that an agreement is in place with the supplier to notify the MAH in case of changes to the medium should be included in section 3.2.S.2.3.

Applicants need to make the proper timely arrangements with their supplier, in order to have this information available at the time of submission of the dossier as the information is a requirement to conclude on the quality and safety of the medicinal product for the CHMP Opinion.

As reminder, the submission of confidential information from third parties directly to EMA (apart from the ASMF for chemical active substances) is not possible and the Applicant needs to have access to this information and include it in the dossier.

 

2. Which information should be provided regarding microbial control of cellculture reagents? October 2024

Cell culture reagents should be of appropriate microbial purity. However assurance of microbial quality is considered to fall under GMP and handled by the company’s pharmaceutical quality system. Therefore, it is not a formal requirement to register a test for sterility of cell culture reagents in the CTD.

 

Cleavable purification tag (His-tag) (3.2.S.2, 3.2.S.4)

 

1. What information should be provided regarding a cleavable purification tag?October 2024

Some proteins are expressed with a cleavable purification tag (e.g. ‘His-tag’) which is removed after initial purification steps. Such purification tags may represent a possible immunogenicity risk. Therefore, the immunogenic/toxicological risk of these impurities should be carefully evaluated and clinically justified. Sufficient data should be provided demonstrating that the manufacturing process and associated control strategy are capable of consistently removing the tag to a sufficiently low and appropriately justified toxicological level. If residual purification tag impurities are present at measurable levels, then an acceptance criterion in the active substance specification or a limit for in-process control (IPC) should be proposed. 

 

Method identification numbers (3.2.S.4.1, 3.2.P.5.1)

 

1. Should method identification numbers be included in the dossier? December2024

Unequivocal identifiers for in-house analytical methods should be included in the specification table. The method descriptions and the method validation summaries should include these in-house method identifiers for the non-compendial methods. This information is required in order to provide a clear link between the release and stability specifications and the descriptions and validations of analytical procedures used for testing. Applicants are free to choose any type of identifier (e.g. name, code, number etc.) provided it is clear and unambiguous. These identifiers are considered different from SOP numbers, which may be site specific and/or subject to changes after minor revisions which do not otherwise require the submission of a variation.

 

Process validation, removal of process related impurities, process related impurities testing (3.2.S.2.5, 3.2.P.3.5)

 

1. Can testing of process related impurities be omitted from drug substance/drugproduct specification? September 2023

It is acceptable not to routinely test for process related impurities if consistent elimination hasbeen demonstrated by validation studies and sufficient batch data is available. Preferably, thereduction of impurities is studied in process evaluation studies by spiking experiments ordemonstration of robust reduction capacity in the relevant manufacturing steps. It should bejustified that the relevant manufacturing step is capable of removing impurities to a sufficientlevel when run under worst-case conditions.

This is not applicable to impurities with a high safety risk and proteinaceous impurities (e.gHCPs),which normally require routine control.

 

Process validation; column/resin re-use qualification (3.S.2.5)

 

1. Is it necessary to provide data from full scale chromatography column/resinre-use,in order to validate resin life-time? October 2024

Full-scale data for chromatography column/resin re-use qualification are normally not required at time of MAA, instead a validation protocol for the post-approval full-scale validation should be provided. However, this protocol and the intended number of re-uses should be supported with appropriate small-scale / process characterisation data provided at MAA.

 

Active substance specification Host cell proteins testing, (3.2.S.3.2, 3.2.S.4.1, 3.2.S.4.5)

 

1. Should a Host Cell Protein test be included in the active substancespecification? September 2023

Host cell protein (HCP) testing is typically part of the active substance specification, as appropriate. Routine control of HCP is deemed important as this may be a relevant safety parameter, i.e. it is not considered appropriate omit HCP testing based on process validation studies only. Until adequate manufacturing experience together with extensive batch data demonstrating consistent low levels of HCP is available, a release specification should be included in S.4.1 for HCP with a clinically qualified upper limit justified in S.4.5. HCP may be tested on an intermediate and reported as a critical in-process control, if the following is fulfilled:

the Applicant has extensive knowledge and control of the manufacturing process (critical process parameters affecting HCP levels should be identified),

scale-down process qualification studies followed by at-scale process validation and batch data results demonstrate HCP clearance,

it is confirmed that exceeding the acceptance criterion for the IPC will lead to batch rejection,

the proposed IPC limit is clinically qualified.

HCP testing will be part of comparability assessments of future process changes where relevant.

Regardless whether HCP is routine tested as an IPC or as a release test, the HCP assay should be well described and validated and acceptance limits should be justified; all documentation should be included in the CTD (either in section S.4 or section S.2.4). The suitability of the detecting polyclonal antibody (coverage of HCP representative of the process, as mentioned in Ph.Eur.2.6.34) should be assessed. In addition, other recommendations from Ph. Eu 2.6.34, should also be addressed by the Applicant.

 

Active substance specifications, sterility (3.2.S.4)

 

1.Should a Biological Active Substance be sterile? October 2024

For biological active substances, information on microbial control is normally expected in the dossier (e.g. in-process or release tests for bioburden, endotoxin, mycoplasma etc., as appropriate). However, unless the biological active substance is explicitly claimed to be sterile by the Applicant, there is no requirement for a sterility specification for a biological active substance, irrespective of its storage conditions (frozen, refrigerated, other). 

 