EMA Questions and answers for biological medicinal products(2)

Dec. 01, 2025

Biosimilar medicinal products: characterization, side-by-side comparison, specification, biosimilarity, analytical comparability (3.2.S, 3.2.S.3.1, 3.2.S.4.1, 3.2.P.5.1, 3.2.R)

 

1. How can specification limits be clinically justified for a biosimilar? September2023

 

Since for most biosimilar applications only a limited number of clinical batches are used, it is not possible to set and clinically justify specification limits solely based on clinical batches of the proposed biosimilar. Therefore, characterisation results of the reference product (as obtained by the applicant using their own qualified/validated test methods intended for the proposed biosimilar) may be used for clinical justification of the specification limits of the proposed biosimilar. Result ranges obtained for marketed reference product batches can be assumed to represent a clinically qualified range for the respective quality parameters.

As regards process-related impurities (e.g. host cell DNA and HCP), since processes are as such not expected to be similar, in most cases the applicant cannot refer to characterisation results from the reference product to justify the specification limits and the control strategy for process-related impurities should be established based on the manufacturing experience for the biosimilar.

 

2. Should a side by side comparison be performed to demonstrate biosimilarity?September 2023

 

In order to demonstrate biosimilarity/analytical comparability, it is not generally required to perform a side by side comparison (i.e. testing data from a single analytical experiment/run). A side by side comparison is important only for those tests with high intrinsic between-run variability, in order to minimize such variability. In other cases, data from different experiments are acceptable.

 

3. When can characterisation testing for Fc functionality of monoclonal antibodies.be omitted? September 2023

 

Where an Applicant can demonstrate that a monoclonal antibody (mAb) binds to a soluble target which has no transmembrane variant or is not known to be cell/membrane-associated, then characterisation testing for Fc functionality assays (ADCC/CDC/ADCP) can be omitted. In such cases, Fc functionality testing is not required to demonstrate comparability after manufacturing changes or for biosimilarity testing.

 

4. What type of ADCC assay methodology is acceptable for demonstratingbiosimilarity of monoclonal antibodies? September 2023

 

The evaluation of ADCC activity should not be based solely on reporter gene assays. A “classical” ADCC assay approach using a two cell format, i.e. target cells plus effector cells (such as NK cells or PBMCs), is required for demonstrating biosimilarity of mAbs with ADCC function.

 

5. For monoclonal antibodies, should binding to polymorphic forms of Fcreceptors be included in biosimilarity studies? September 2023

 

Where binding to Fc?RIIa is a relevant quality parameter, the biosimilarity exercise should include binding to both polymorphic receptor variants 131H and 131R.

Where binding to Fc?RIIIa is a relevant quality parameter, the biosimilarity exercise should include binding to both polymorphic receptor variants 158V and 158F.

 

6. What information should be provided regarding effector functions of IgG2monoclonal antibodies(mAbs)?October 2024

 

Concerning Fc effector functions for mAbs of the IgG2 subclass, it is acknowledged that they are expected to show low binding activity to Fcγ receptors. However, in case of a biosimilar application, to confirm analytical similarity between a reference product and a biosimilar, binding to C1q and relevant FcγRs should be investigated. In case similar binding to Fc receptors and C1q is demonstrated, a comparative assessment of functional assays for Fc-dependent activities may not be required. However, if relevant differences in FcγRs or Cq1 binding are observed, then relevant activities (antibody-dependent cell-mediated cytotoxicity (ADCC), antibody-dependent cellular phagocytosis (ADCP), and complement-dependent cytotoxicity (CDC)) should be evaluated.

 

Monoclonal antibodies specification, ADCC activity (3.2.S.4.1, 3.2.P.5.1)

 

1. What specification tests are required for routine control of the ADcc activity ofmonoclonal antibodies? September 2023

 

For mAbs with Antibody Dependent Cell-mediated Cytotoxicity (ADCC) activity, it is sufficient to only have one parameter in the specifications that verifies this function. Possible tests include a cellular ADCC assay, Fc?RIIIa binding, or relevant testing of the glycoprofile; the two latter parameters being more reliable, one of them is to be preferred to the ADCC assay depending on their correlation to ADCC assay. Indeed, where control of effector function is based on testing of the Fc?RIIIa binding or the glycoprofile, a correlation should be demonstrated between ADCC and the proposed Fc?RIIIa binding assay or the glycosylation parameters. Depending on the specific molecule, control may be based on afucosylation (G0+G1+G2), high mannose forms (e.g. M5+M6+M7+M8), total afucosylation (G0+G1+G2+high mannose forms) or a combination of several of these parameters, whatever is most relevant as indicator for ADCC.

 

Transport validation (3.2.P.3.5)

 

1. What data should be submitted to substantiate transport validation? October2024

 

For biological products, a product-specific transport validation study is generally not required. Instead, stability during transport can be justified based on (a combination of) prior knowledge and simulated/laboratory transport studies. The Applicant should also confirm that the temperature is routinely monitored throughout shipping. However, for products that may be more susceptible to the effects of transport, such as cell therapies, product-specific data is typically expected. The use of surrogate markers should be justified.

 

Polysorbate testing in finished product specification (3.2.P.5)

 

1. Should a test for polysorbate be included in the finished product specification?September 2023

 

Where polysorbate is included in the finished product formulation and it has been demonstrated in formulation development studies that polysorbate is a relevant component to prevent particle formation, or that particle formation is linked to polysorbate degradation, a test for polysorbate should be included not only in the routine release but also in the stability specifications. Alternatively, sufficient pharmaceutical/formulation development data to demonstrate that polysorbate levels remain stable over the proposed shelf life of the finished product, could be provided to substantiate omission of such a test during stability studies.

 

Low Endotoxin Recovery, Endotoxin masking effect (3.2.P.5.3)

 

1.When should Low Endotoxin Recovery (LER, also known as 'endotoxinmasking')be investigated? Rev. May 2025

 

LER (low endotoxin recovery) refers to the reduced ability to detect spiked endotoxin in products tested using the compendial Limulus Amebocyte Lysate (LAL) assay or recombinant Factor C based assay 1. This phenomenon may be due to endotoxin masking, and its causes are not completely understood. Current knowledge suggests that LER is inherent to certain product formulations. Thus, for product formulations that contain a combination of a surfactant (e.g. polysorbate) and a chelator (e.g. EDTA, citrate, phosphate, histidine), LER studies should be submitted in the Marketing Authorisation (MA) dossier.

LER studies, requested in a MA, should be performed by spiking undiluted samples with known amounts of endotoxin and by monitoring the recovery over specific time intervals. LER studies should reflect conditions relevant for the manufacturing process, including relevant temperatures, and should reflect potential hold times during manufacture.

Based on current scientific state of the art, a minimum of four time-points should be evaluated to ensure valid and accurate results. Two consecutive data points falling below 50% recovery (lower compendial limit), should be considered as LER.

If LER is detected, the Applicant should propose an adequate mitigation strategy (e.g. the compendial method should be optimized or an alternative method developed). For LER exhibiting products, it is strongly recommended to set the finished product specification limit for bacterial endotoxin as low as reasonably achievable, according to actual manufacturer`s data. This approach would help to ensure that a larger safety margin is built into the finished product endotoxin specification limit. The recommended location of the LER studies is CTD section 3.2.P.5.3 (validation of analytical procedures) or CTD 3.2.P.2.3 (manufacturing process development) with a cross-reference in 3.2.P.5.3, as appropriate.

Of note, quality control (QC) sample hold-times and storage conditions are distinct from hold time applied during LER studies. Indeed, QC samples may be diluted and/or frozen prior to testing, while this is not the case for LER studies.  The appropriateness of the QC samples respective hold time i.e. maximum allowable time between sampling and testing, is a general GMP requirement 2.

LER investigations should focus on the finished product (FP) as it is administered to the patient. LER studies may not be necessary for the active substance (AS) if the matrix is similar for both AS and FP. However, if there are differences in the matrix, a risk assessment should be performed to evaluate whether LER testing on the FP is sufficiently representative for the AS.

PDA Technical Report No. 82 on LER is recognised as a relevant standard for designing LER studies and could therefore be considered by Applicants when designing LER studies. Although the technical report primarily focuses on protein-based products, in the absence of specific guidance, it can also be consulted for other products such as vaccines and gene therapy.

 

Source: EMA

 